Tag Archives: insulation

Home & Greenhouse Insulation Extra Heavy Duty Extra Large Bubbles Clear Wrap

Posted on by
Home_Greenhouse_Insulation_Extra_Heavy_Duty_Extra_Large_Bubbles_Clear_Wrap_01_xf Home & Greenhouse Insulation Extra Heavy Duty Extra Large Bubbles Clear Wrap
Home & Greenhouse Insulation Extra Heavy Duty Extra Large Bubbles Clear Wrap
Home & Greenhouse Insulation Extra Heavy Duty Extra Large Bubbles Clear Wrap
Home & Greenhouse Insulation Extra Heavy Duty Extra Large Bubbles Clear Wrap

Home & Greenhouse Insulation Extra Heavy Duty Extra Large Bubbles Clear Wrap
Thank you for viewing my listing. HOME & GREENHOUSE INSULATION. THE TOUGHEST BUBBLE WRAP EVER. NOT AVAILABLE IN STORES. IDEAL FOR COMPUTERS, ELECTRONICS OR LARGE ITEMS. SUPPORT AUSTRALIAN MADE PRODUCT. THIS IS THE BIG DADDY OF BUBBLE WRAP. 5 METER LONG (20 FEET). 32MM (1 1/4) DIAMETER BUBBLES. 13 MM THICK (1/2) BUBBLES. THIS IS THE BIG DADDY OF ALL BUBBLE WRAP. MORE ECONOMICAL THAN STANDARD SIZE BUBBLES WITH SAME LENGTH. EXTRA HEAVY DUTY BUBBLE WRAP. DOUBLE SIDED LARGE BUBBLES. BIG BUBBLES – NO TROUBLES. This is a high quality industrial strength Bubble Wrap. This listing is for Bubble Wrap – BUBBLE WRAP CUSHIONING, with large bubbles on both sides to provide extra protection. This listing is for the industrial strength Bubble Wrap – Not available in stores. Available only through this listing. Super heavy duty bubblewrap provides ultimate protection for your products. Double sided reinforced with large bubbles for extra strength. Perfect for wrapping difficult items which require extra strength, would, electrical or electronic items, glass, pottery, furniture, or any other items requiring ultimate protection. Traditional Bubble wrap will normally burst or deflate. Protects products from shock, abrasion and vibration. This Bubble Wrap is the wide 1,500 mm. Ideal for furniture, automotive spare parts, antique, electronics, Hi Fi, or anything else. The combination of extra width and extra large bubbles means more protection and less cost. Wrap each item with bubble wrap to protect and cushion against any shock that occurs when the items come in contact with each other or if the boxes receive any trauma. If you can feel the item and not the air bubbles, there could be a risk of damage. Tear and puncture resistance. Optimal edge and corner protection. Superior protection and reusable. Prevents goods from moving in transit. Enables clear product identification. Bubble will not go flat. Products protected through entire distribution cycle. Anti Static – Ideal for computers, electronics. Extra large bubbles – Ideal for furniture, large items, glass or pottery. Improve your product presentation with this unique Bubble Wrap. Protect your packages with this Bubble Wrap. The guidelines are to allow at least two inches or 5 cm of padding between the packaged material and the inside of the box. The test you should apply when wrapping items is to totally enclose your item with the bubble wrap. When touching the wrapped item, you should only feel the air bubbles and not the item itself. It is convenient, just tear. And use as much or as little as you want. It is also reasonably priced. All quality products at bargain prices. Occasionally, I list the same item with discounted prices for a limited time. BUBBLE WRAP AS INSULATION MATERIAL. Bubble Wrap is very versatile. Apart from its excellent packaging features, it is a very effective and economical insulation material. This is a simple technique for insulating windows with bubble wrap packing material. Bubble wrap is often used to insulate greenhouse windows in the winter, but it also seems to work fine for windows in the house. You can use it with or without regular or insulating window shades. It also works for windows of irregular shape, which can be difficult to find insulating shades for. It may also work in summer to insulate the wals and roof of the house to keep the cool air inside. Cut the bubble wrap to the size of the window pane with scissors. Spray a film of water on the window using a spray bottle. Apply the bubble wrap while the window is still wet and press it into place. The bubble side goes toward the glass. To remove the bubble wrap, just pull it off starting from a corner. You can save it and use it for several years. It does not leave a mess or stains on the window glass. Takes just: 30 minutes. Give your plants a helping hand through winter by adding a layer of bubble wrap to insulate your greenhouse. You’ll have fewer draughts and will also benefit from lower bills if you use a heater during the very cold months. Also available other size bubbles and roll widths. The complete Stimulus Package!! TO VIEW ALL BUBBLE PACKING MATERIAL. USING BUBBLE WRAP TO’DOUBLE GLAZE’ YOUR WINDOWS TO KEEP YOUR HOUSE COOL IN SUMMER. Using bubble wrap on windows helps to trap hot air. It can act as a cheap alternative to double glazing, according to a scientist that specialises in designing homes. You can put bubble wrap on your windows in winter to keep your environment warm during the cold weather, but you can also use it in summer to keep your environment cool. You can convert a single glazed window into something that is much more like a double glazed window by simply putting bubble wrap over the glass. The bubble wrap should also cover the metal window frames, which are really conductive. Bubble wrap works by increasing the isolative value of the window, making it effective in keeping the heat out in summer and preventing heat loss in winter. The still layer of air trapped in the bubbles gives a cheap double-glazed-type effect. Hot summer days can leave a poorly insulated house feeling like a sauna. Once the sun hits that glass it travels through that glass into the house. The house absorbs that heat in all sorts of different ways, and you don’t lose that heat very easily. FUN AND GAMES WITH BUBBLE WRAP. Apart from its great packing material properties,, there have also been other things that people have been doing with bubble wrap. If you look around online, you will find that there are people who make bubble wrap arts and crafts for fun. Bubble wrap sculptures and figurines are particularly popular, and many parents make their children bubble wrap toys for fun. That little boy may have bubble wrap plastic gloves while that little girl has a bubble wrap ball. The strangest bubble wrap creations, however, are bubble wrap clothing. Yes, people actually make clothes out of bubble wrap! Whether it’s just a simple skirt, a shirt, a whole men’s outfit, or a full-blown wedding dress, they all exist. Some stores even sell bubble wrap bikinis and underwear! Bubble wrap clothing is usually made at home by various people who want to try wearing this form of cushioning. Bubble wrap can be bought in large sheets or rolls that people treat like fabric and cut and tape around. The same patterns for normal clothes can be used for bubble wrap, though you can opt to not sew it anymore but instead stick the parts together with transparent tape. Can you imagine walking around while being able to pop all those bubbles? It would be fun, not to mention attention-catching. They even have bubble wrap fashion contests. BUBBLE WRAP FOR STRESS RELIEF Popping Your Way to Stress Relief Believe it or not bubble wrap can help you relieve some stress, although it won’t solve any advanced cases. Bubble wrap is a magnet for stress! Bubble wrap seems to have some magical quality for stress relief. The use of bubble wrap for stress relief is a modern, novel, 100% natural and organic method for the treatment of stress relief which does not involve any use of drugs. The continued popping noise and the feeling that it generates naturally relax you and soon you realize that nothing else matters but the rhythmic popping of the bubbles in front of you. The popping noise itself and the feeling you get by doing it is a natural stress reliever and you’ll soon find yourself popping every bubble that you can find. So, not only is bubble wrap a very versatile wrapping material, it’s simultaneously an effective stress reliever! You can pop away creating a unique rhythm, that you alone feel, that melts away your stress. So the next time you are stressed out, don’t punch the wall or throw a coffee mug, grab a few pieces of bubble wrap. Squeeze it, twist it, pop it until you achieve that feeling of peace… Only then have you truly achieved stress relief from bubble wrap! Public holidays and weekends excluded. However, there is no guarantee that you will receive your parcel by the estimated date. If you wish to have your item delivered or handled in a special manner, let me know and I will inform you if there is any additional charge. If you live in a remote location with no courier service, let me know. Delays may be experienced in case of work overload, postal or courier delays, public holidays and weekends, or shortage of stock. If premises unattended, leave in a secure location. If premises unattended, place a card in the mailbox and leave parcel at nearest collection point. If the parcel is sent by courier, a signature is usually required. If it is not safe to leave the parcel by Your front door, then you will need to sign for it. All parcels will be securely packaged. Otherwords, all care taken and no responsibility accepted. No responsibility can be taken if you fail to provide a telephone number. Please note, I assume no responsibility if the item is delayed, lost or damaged n transit. No compensation will be paid until such investigation has been concluded. International Buyers – Please Note. I strive to please my fellow eBayers. If you have any issue with the item, let me know. Errors & Omissions Excluded. No other warranties either expressed or implied are offered. You may find similar items cheaper with other sellers or retailers. I also rely on sighted assistants to help with the pictures and description. If you prefer to trade with a behemoth, please go elsewhere. From time to time I offer the same item cheaper for a limited period. The description of the items is as provided by the principal sellers and believed to be reliable. All feedback will be reciprocated. If you are happy with my service, tell the whole world, if you are not happy, tell me. If you have any issue with the item, contact me first before you post negative or neutral feedback. Issues can be resolved amicably. Leaving damaging feedback before your attempt to resolve any issue first will be deemed as defamatory and in contravention of the terms and conditions and will be dealt with accordingly. The bad Karma will result in proceedings for the removal of such feedback and will give rise of a liquidated claim for damages. Any unwarranted negative or neutral feedback will be removed using legal processes and may give rise to a liquidated claim for defamation or/ and breach of contract. All issues can be resolved amicably. If you have an issue, contact me first. If you have any issues with your item, let me know and I will be happy to rectify any problem. If you post negative or neutral feedback without first letting me know of your intention to post such feedback will be deemed defamatory and may give rise to proceedings for defamation and/or breach of contract and will give rise to a liquidated claim for damages. If you have in issue, it would be quicker to contact me first and I will do my utmost to help you. If you do not wish to have feedback posted for you – for privacy reasons or otherwise – just let me know and I will not post feedback for you or simply do not post feedback for me. All brand names & trademarks are the property of their respective holders and are referred to here for descriptive purpose only. The listed brand names and model designations are intended only to show the compatibility of these products with various products. Pictures are for descriptive purposes only. All dimensions and measurements are approximate. Colour is as shown unless otherwise stated. Colour may vary depending on lighting, your computer screen resolution or angle of viewing. Please exercise care when you open your package when you receive it. Do not slash the packing material with a knife as to damage the contents of the package. Open carefully so you don’t drop the contents in case of fragile or breakable items. If the information is not correct, please provide your correct contact information. You agree to abide by the herein Terms & Conditions and any further amendments. Any dispute arising out of this agreement or the interpretation thereof shall be decided and settled in accordance with the laws and statues of the incumbent legislation or any future legislations as decided by a competent court, tribunal or by any deliberative assembly. Cash in person or Bank Deposit. This item is in the category “Industrial\Material Handling\Packing & Shipping\Shipping & Cushioning Supplies\Bubble Cushioning Wrap”. The seller is “eddiesolomon777″ and is located in this country: AU. This item can be shipped worldwide.
  • Length: 2.5 METERS – 10 FEET
  • Format: Roll
  • Features: Anti-Static, Heavy Duty
  • Bubble Size: EXTRA LARGE
  • Brand: Eddie Solomon
  • UPC: 722197213277

Home & Greenhouse Insulation Extra Heavy Duty Extra Large Bubbles Clear Wrap

Heavy Duty Double Foil Air Bubbl Cell Insulation 75 Sq M. Free Shipping

Posted on by
Heavy_Duty_Double_Foil_Air_Bubbl_Cell_Insulation_75_Sq_M_Free_Shipping_01_xu Heavy Duty Double Foil Air Bubbl Cell Insulation 75 Sq M. Free Shipping
Heavy Duty Double Foil Air Bubbl Cell Insulation 75 Sq M. Free Shipping
Heavy Duty Double Foil Air Bubbl Cell Insulation 75 Sq M. Free Shipping
Heavy Duty Double Foil Air Bubbl Cell Insulation 75 Sq M. Free Shipping
Heavy Duty Double Foil Air Bubbl Cell Insulation 75 Sq M. Free Shipping
Heavy Duty Double Foil Air Bubbl Cell Insulation 75 Sq M. Free Shipping

Heavy Duty Double Foil Air Bubbl Cell Insulation 75 Sq M. Free Shipping
Thank you for viewing my listing. DOUBLE SIDED SILVER FOIL. TWO LAYERS OF FOIL. REDUCE RADIANT HEAT TRANSFER. IDEAL FOR HOT OR COLD CLIMATE. 75 SQUARE METERS (825 SQUARE FEET). 10 MM (3/8) DIAMETER BUBBLES. 4 MM THICK (3/16) BUBBLES. TWO LAYERS OF ALUMINUM FOIL. Call Eddie Solomon if you have any question. Please Note: this product does not comply with Australian Standards nor the Building Code but it is tested by Australian CSIRO and has been used widely for home insulation. TO VIEW ALL FOIL BUBBLE INSULATION. SILVER FOIL BUBBLE INSULATION. Double Foil Insulation is available in 75 Square Meters rolls – 1,500 mm wide x 50 Meters long. It consists of a layer of polyethylene bubbles that is sandwiched between two layers of 99% pure aluminum radiant barrier foil. This style can be used in a variety of applications because it’s light weight and easy to handle yet provides superior protection. The bubble center creates maximum R-Value and the reflective foil on both sides allow it to reflect 97% of radiant heat away from a structure on the outside and back in on a structure from the inside. This is why it works effectively in both hot and cold climates. Double Foil Reflective Insulation is a versatile insulation consisting of an 4.8 mm thick – 10 mm diameter layer of polyethylene bubbles sandwiched between two sheets of highly reflective, 99% aluminum. Reflective Bubble Insulation provides superior reflectivity of radiant heat while providing protection against conductive heat gain and loss as well as performing as a vapor barrier. Nominal Thickness 1/4 – 0.6 mm. Weight 0.5 oz / sq. Ft – 160 g/sq m. Temperature Range – ASTM C411 -50 F to 180 F (-45 c to 82 c). Flame Spread (ASTM E84-05) 5. Smoke Development (ASTM E84-05) 5. Emissivity – ASTM C1371 0.03-0.04. Reflectivity – ASTM 3903 0.96-0.97. Water Vapor Permeance-ASTM E96. Flexibility – No Cracking. Resistant to Fungi and Bacteria Does not promote growth. ADVANTAGES OF THIS PRODUCT. Very effective in warmer climates. No change to thermal performance over time due to compaction, disintegration or moisture absorption. Thin sheets takes up less room than bulk insulation. Can act as a vapor barrier. Will not mold or mildew. Radon retarder, will limit radon penetration through the floor. This is a high quality industrial strength Double Foil Insulation Bubble Wrap. Long lasting, heavy duty nylon barrier layer to increase longevity. Bubble Wrap is Lightweight and easy to use. It is an inexpensive solution to your insulation needs. This 75 Square meter Silver Insulation Foil Bubble Wrap usually comes in rolls of 1,500 mm wide. However, it may come in other widths totalling 75 Square meter depending on availability. Our standard single and double bubble foil insulation is. Silver foil Available in a range of widths, from. 375 mm 15″ to 1,500 mm (60″), and lengths. We offer double-sided Silver. Aluminium products, as well as products covered with Silver Foil. On one side and white polyethylene on the other. This durable bubble insulation will withstand temperatures between -50 degrees Celsius. And 82 degrees Celsius (180 degrees Fahrenheit), making it ideal for both attic and flooring installations. Be sure to check out our silver Foil Aluminium. This is the best tape for bubble foil insulation because it ensures the continuity of the reflective surface, which is essential for getting the most from your installation. Radiant floor heating has been in use for centuries and radiant barriers help to retain the heat generated by the radiant heating system blocking it from escaping into the ground. Silver foil bubble Wrap. Insulation is extremely tough and pliable, easy to install, and is an excellent vapor barrier for all your radiant floor heating applications, thus greatly reducing your electricity or gas bills. Silver Foil Bubble wrap. Insulation installed in crawl spaces below a building structure reflect the heat flows that are flowing downward from the flooring back up into the flooring at a 95-97% rate providing increased comfort and heat retention. The temperature of the cold floors which cause cold feet will be raised while your heating bill is reduced, providing for increased comfort. As heat is reflected back into the living area, it warms other objects which then radiate heat back into the room, further increasing your living comfort. Metal & Steel Buildings. Temperature sensitive storage areas. Silver foil Bubble Wrap. Insulation applications are only limited by your imagination. The main feature of this insulation is its reflective nature and not the thickness of the material. It has a nominal thickness of 4.8 mm and easy to handle. We can also custom make any combination to suit your requirements. You can have foam sandwiched between two layers of Silver foil, Or thicker bubbles between tow layers of foil, or any combination you require. Please note custom made insulation attracts minimum order of 1,500 Square meters. Custom orders are final. All the insulation is made right here in Australia with the highest standard of material and manufacture. The following Test Report conducted by the Australian CSIRO on the single Foil Bubble Insulation. This listing is for the Double Foil Bubble Insulation which commands a higher insulation quality tham the single. CSIRO- Materials Science & Engineering. (ABN: 41 687 119 230). Henry St, Belmont, Victoria 3216, Australia. Page 1 of 1. Sample Description: silver insulation material designed for pallet protection. At an ambient temperature of 23.1ºC – difference from face to back 2.4ºC. At an ambient temperature of 28.6ºC – difference from face to back 5.1ºC. OF THE INSULATIVE EFFECTIVENESS OF SINGLE-SIDED 10 MILLIMETRE BUBBLE FILM (4.8 mm Thick). LAMINATED WITH METALLISED P. THE TRUTH ABOUT R VALUE. Around most of the world, R-values are given in SI units, typically square-metre kelvin per watt or m2·K/W (or equally, m2·°C/W). In the United States customary units, R-values are given in units of ft2·°F·hr/Btu. It is particularly easy to confuse SI and US R-values, because R-values both in the US and elsewhere are often cited without their units, e. Usually, however, the correct units can be inferred from the context and from the magnitudes of the values. United States R-values are approximately six times SI R-values. The conversion between SI and US units of R-value is 1 h·ft2·°F/Btu = 0.176110 K·m2/W, or 1 K·m2/W = 5.678263 h·ft2·°F/Btu. As an example an R11 in the United States is approximately R2 in SI units in Europe, Australia and the rest of the world. An R value advertised by a United States merchant may appear more appealing as the US R value is 6 times higher than SI values used in the rest of the world. It does not mean that a US R value is more effective than An R value used in Europe, Australia or the rest of the world. Do not rely on the R value provided by the supplier as the R value may increase or decrease depending on the application. Furthermore, the actual R value of the insulation depends entirely on the application and how you apply the insulation. An R 2 value may increase or decrease depending on how the insulation is applied. With the Silver Foil bubble Insulation you will need an air pocket between the surface. Of the structure you are insulating. And the insulation material. The air pocket has its own r value depending on the width of the air pocket thus increasing the R value of the insulation material. Conversely, if you apply the insulation material directly on the surface of the structure will defeat the purpose of insulation because the insulation material will act as a heat conductor and will end up heating the premises in the hot summer and will also be counterproductive in winter. Radiation is minimized by low emissivity (highly reflective) exterior surfaces such as aluminum foil. Lower thermal conductivity, or higher R-values, can be achieved by allowing an air gap between the surface of the structure and the aluminium foil. The air gap will act an heat pocket where heat will accumulate instead of being circulation inside your structure. Trapped air has its own R value. The R value of trapped air depends on how much gap is between the insulation material an the structure. A wider gap will produce a greater R value and a narrower. Gap will produce a smaller R value. Air by itself has no R value; only trapped air will produce an R value. However, if you allow a very wide gap, the air will not be trapped and may reduce your R value and cause an opposite result. The R-value is a measure of an insulation sample’s ability to reduce the rate of heat flow under specified test conditions. The primary mode of heat transfer impeded by insulation is conduction, but insulation also reduces heat loss by all three heat transfer modes: conduction, convection, and radiation. The primary means of heat loss across an uninsulated air-filled space is natural convection, which occurs because of changes in air density with temperature. Insulation greatly retards natural convection making the primary mode of heat transfer conduction. To find the heat loss per square meter, simply divide the temperature difference by the R value. If the interior of a home is at 20 °C, and the roof cavity is at 10 °C, the temperature difference is 10 C° (= 10 K difference). Assuming a ceiling insulated to R-2 (R = 2.0 m2K/W), energy will be lost at a rate of 10 K/2 K·m2/W = 5 watts for every square meter of ceiling. Doubling the thickness of the insulation material or even doubling the thickness of the trapped air layer doubles the R value. This does not hold for compressed bats of glass wool because compressing the bats does not proportionally increase the r value. Furthermore, doubling the thickness of the Silver Foil Bubble Insulation does not double the R value of the insulation material. The main feature of the Silver Backed Bubble Insulation is its reflective nature and not its thickness. To Double the R value of the Foil Bubble Insulation you will need to create a heat pocket which hads it s own R value that can be added to the R value of the Foil Insulation. As an example, the if Foil Bubble Insulation has an R value of r2 and the. Heat pocket has an R value of R 1,5, both R value are added together to achieve an R value of R3.5 in SI units or R19 in United States standards. As discussed earlier porous material such as foam and bats does not allow the full potential of trapped air to be established and will not give you the proportional R value relative to thickness. In calculating the R-value of a multi-layered installation, the R-values of the individual layers are added:[10]. R-value(outside air film) + R-value(brick) + R-value(sheathing) + R-value(insulation) + R-value(plasterboard) + R-value(inside air film) = R-value(total). To account for other components in a wall such as framing, an area-weighted average R-value of the whole wall may be calculated. For the most part, testing the R-value of insulation is done at a steady temperature, usually about 70 °F (21 °C) with no surrounding air movement. Since these are ideal conditions, the listed R-value for insulation will almost certainly be higher than it would be in actual use, because most situations with insulation are under different conditions. Some types of foam insulation, such as polyurethane and polyisocyanurate are blown with heavy gases such as chlorofluorocarbons (CFC) or hydrochlorofluorocarbons (HFCs). However, over time a small amount of these gases diffuse out of the foam and are replaced by air, thus reducing the effective R-value of the product. This has led to controversy as how to rate the insulation of these products. Many manufacturers will rate the R-value at the time of manufacture; critics argue that a more fair assessment would be its settled value. [citation needed] The foam industrywhen? Adopted the LTTR (Long-Term Thermal Resistance) method, [14] which rates the R-value based on a 15 year weighted average. However, the LTTR effectively provides only an eight-year aged R-value, short in the scale of a building that may have a lifespan of 50 to 100 years. Note that these examples use the non-SI definition and/or given for a 1 inch (25.4 mm) thick sample. Vacuum insulated panels have the highest R-value (approximately R-45 per inch in American customary units); aerogel has the next highest R-value (about R-10-30 per inch), followed by isocyanurate and phenolic foam insulations with, R-8.3 and R-7 per inch, respectively. They are followed closely by polyurethane and polystyrene insulation at roughly R-6 and R-5 per inch. Loose cellulose, fiberglass (both blown and in batts), and rock wool (both blown and in batts) all possess an R-value of roughly R–2.5 to R–4 per inch. Straw bales perform at about R-1.5. However, typical straw bale houses have very thick walls and thus are well insulated. Snow is roughly R-1. The effective thermal resistance of an enclosed air cavity is strongly influenced by radiative heat transfer and distance between the two surfaces. All quality products at bargain prices. Occasionally, I list the same item with discounted prices for a limited time. Please Note: Due to the bulky size of this insulation, the 75 Square Meters are sent as follows. 1 Roll of 75 square meters – 1,500 mm wide 50 m long. 2 Rolls of 37.5 Square meters – 1,500 mm wide 25 m long each. 2 rolls of 37.5 Square meters each – 750 mm wide 50 m long. Public holidays and weekends excluded. However, there is no guarantee that you will receive your parcel by the estimated date. The most economical method. If you wish to have your item delivered or handled in a special manner, let me know and I will inform you if there is any additional charge. If you live in a remote location with no courier service, let me know. Delays may be experienced in case of work overload, postal or courier. Delays, public holidays and weekends, or shortage of stock. If premises unattended, leave in a secure location. If premises unattended, place a card in the mailbox and leave parcel at nearest collection point. The parcel shall be deemed to have been delivered. If the parcel is sent by courier, a signature is usually required. You can select that the courier leaves the parcel. If it is not safe to leave the parcel by Your front door, then you will need to sign for it. All parcels will be securely packaged. For its loss or damage. Otherwords, all care taken and no responsibility accepted. No responsibility can be taken if you fail to provide a telephone number. Please note, I assume no responsibility if the item is delayed, lost or damaged n transit. No compensation will be paid until such investigation has been concluded. You will also need to arrange for your own packaging. International Buyers – Please Note. I strive to please my fellow eBayers. If you have any issue with the item, let me know. Errors & Omissions Excluded. No other warranties either expressed or implied are offered. You may find similar items cheaper with other sellers or retailers. I also rely on sighted assistants to help with the pictures and description. If you prefer to trade with a behemoth, please go elsewhere. From time to time I offer the same item cheaper for a limited period. The description of the items is as provided by the principal sellers and believed to be reliable. All feedback will be reciprocated. If you are happy with my service, tell the whole world, if you are not happy, tell me. If you have any issue with the item, contact me first before you post negative or neutral feedback. Issues can be resolved amicably. Leaving damaging feedback before your attempt to resolve any issue first will be deemed as defamatory and in contravention of the terms and conditions and will be dealt with accordingly. The bad Karma will result in proceedings for the removal of such feedback and will give rise of a liquidated claim for damages. Any unwarranted negative or neutral feedback will be removed using legal processes and may give rise to a liquidated claim for defamation or/ and breach of contract. All issues can be resolved amicably. An issue, contact me first. If you have any issues with your item, let me know and I will be happy to rectify any problem. If you post negative or neutral feedback without first letting me know of your intention to post such feedback will be deemed defamatory and may give rise to proceedings for defamation and/or breach of contract and will give rise to a liquidated claim for damages. If you have in issue, it would be quicker to contact me first and I will do my utmost to help you. If you do not wish to have feedback posted for you – for privacy reasons or otherwise – just let me know and I will not post feedback for you or simply do not post feedback for me. All brand names & trademarks are the property of their respective holders and are referred to here for descriptive purpose only. The listed brand names and model designations are intended only to show the compatibility of these products with various products. Pictures are for descriptive purposes only. All dimensions and measurements are approximate. Colour is as shown unless otherwise stated. Colour may vary depending on lighting, your computer screen resolution or angle of viewing. Please exercise care when you open your package when you receive it. Do not slash the packing material with a knife as to damage the contents of the package. Open carefully so you don’t drop the contents in case of fragile or breakable items. If the information is not correct, please provide your correct contact information. You agree to abide by the herein Terms & Conditions and any further amendments. Any dispute arising out of this. Agreement or the interpretation thereof. Shall be decided and. Settled in accordance with the laws and statues of the State of New South Wales, Australia. The parties agree that the venue shall be Sydney, New south Wales. This item is in the category “Home & Garden\Other Home & Garden”. The seller is “eddiesolomon777″ and is located in this country: AU. This item can be shipped worldwide.
  • Product Type: Silver Foil Bubble Wrap Insulation
  • Modified Item: No
  • Style: Double Sided Foil
  • Custom Bundle: No
  • Type: Roll
  • MPN: SFBI2
  • Brand: EDDIE SOLOMON
  • UPC: 722197213239

Heavy Duty Double Foil Air Bubbl Cell Insulation 75 Sq M. Free Shipping
Category: heavy | Tags: , , , , , , , ,

Silver Foil Cell Air Bubble Insulation 30 Sqm 750mm W Australian Csiro Tested

Posted on by
Silver_Foil_Cell_Air_Bubble_Insulation_30_Sqm_750mm_W_Australian_Csiro_Tested_01_dbp Silver Foil Cell Air Bubble Insulation 30 Sqm 750mm W Australian Csiro Tested
Silver Foil Cell Air Bubble Insulation 30 Sqm 750mm W Australian Csiro Tested
Silver Foil Cell Air Bubble Insulation 30 Sqm 750mm W Australian Csiro Tested
Silver Foil Cell Air Bubble Insulation 30 Sqm 750mm W Australian Csiro Tested
Silver Foil Cell Air Bubble Insulation 30 Sqm 750mm W Australian Csiro Tested
Silver Foil Cell Air Bubble Insulation 30 Sqm 750mm W Australian Csiro Tested

Silver Foil Cell Air Bubble Insulation 30 Sqm 750mm W Australian Csiro Tested
Thank you for viewing my listing. REDUCE RADIANT HEAT TRANSFER. IDEAL FOR HOT & COLD CLIMATE. ALSO AVAILABLE THE DOUBLE FOIL BUBBLE INSULATION. VIEW MY OTHER LISTINGS FOR THE COMPLETE RANGE. TESTED BY AUSTRALIAN CSIRO. 750 MM WIDE (30). 40 METRES LONG (130 FEET). 10 MM (3/8) DIAMETER BUBBLES. ALSO AVAILABLE THE EXTRA HEAVY DUTY EXTRA THICK FOIL BUBBLE INSULATION. TO VIEW ALL FOIL BUBBLE INSULATION. Call Eddie Solomon if you have any question. THE CHINESE AND IMPORTED INSULATION COMES IN 1,200 MM WIDE. THIS AUSTRALIAN MADE PRODUCT COMES IN 1,500 MM AND 750 MM WIDE. SINGLE SILVER FOIL BUBBLE INSULATION. For larger rolls, please refer to my other listings. Also available double foil and extra thick extra heavy duty foil bubble insulation. Single Foil Insulation is available in various size rolls. It consists of a layer of polyethylene bubbles and a layer of 99% pure aluminum radiant barrier foil. This style can be used in a variety of applications because it’s light weight and easy to handle yet provides superior protection. The bubble layer creates maximum R-Value and the reflective foil allows it to reflect 97% of radiant heat away from a structure on the outside and back in on a structure from the inside. This is why it works effectively in both hot and cold climates. Single Foil Reflective Insulation is a versatile insulation consisting of a – 10 mm diameter -layer of polyethylene bubbles backed by a sheet of highly reflective, 99% aluminum. Reflective Bubble Insulation provides superior reflectivity of radiant heat while providing protection against conductive heat gain and loss as well as performing as a vapor barrier. Also available double Foil Insulation Bubble Wrap for ultimate protection and higher R value. Also available rolls of 75 Square Meters, 450 Square Meters, 600 Square Meters in both single Foil or Heavy Duty Double Foil or Extra Heavy Duty Double Foil Extra thick bubbles. Foil bubble insulation is ideal for metal building and commercial roof applications where the product will be seen and where aesthetics are important. The reflective surface can even make an area brighter, effectively cutting down on the electricity needed to meet lighting requirements. Foil bubble wrap can also be applied to windows to keep out the glare of the sun, and also to keep heat in or out depending on the weather. This is Foil lined Bubble Wrap on one side. Also available Silver Foil Insulation reinforced Tape. This listing is for Single Foil Bubble Insulation. Double Foil bubble Insulation as also available. Minimum order for Double Foil is 75 Sq M. ADVANTAGES OF THIS PRODUCT. Very effective in warmer climates. No change thermal performance over time due to compaction, disintegration or moisture absorption. Thin sheets takes up less room than bulk insulation. Can act as a vapor barrier. Will not mold or mildew. Radon retarder, will limit radon penetration through the floor. For a demonstration on the use of Silver Foil Bubble Insulation. Our standard single and double bubble foil insulation is. Silver foil Available in a range of widths, from. 375 mm 15″ to 1,500 mm (60″), and lengths. We offer double-sided Silver. Aluminium products, as well as products covered with Silver Foil. On one side and white polyethylene on the other. This durable bubble insulation will withstand temperatures between -50 degrees Celsius. And 82 degrees Celsius (180 degrees Fahrenheit), making it ideal for both attic and flooring installations. Be sure to check out our silver Foil Aluminium. This is the best tape for bubble foil insulation because it ensures the continuity of the reflective surface, which is essential for getting the most from your installation. Radiant floor heating has been in use for centuries and radiant barriers help to retain the heat generated by the radiant heating system blocking it from escaping into the ground. Silver foil bubble Wrap. Insulation is extremely tough and pliable, easy to install, and is an excellent vapor barrier for all your radiant floor heating applications, thus greatly reducing your electricity or gas bills. Silver Foil Bubble wrap. Insulation installed in crawl spaces below a building structure reflect the heat flows that are flowing downward from the flooring back up into the flooring at a 95-97% rate providing increased comfort and heat retention. The temperature of the cold floors which cause cold feet will be raised while your heating bill is reduced, providing for increased comfort. As heat is reflected back into the living area, it warms other objects which then radiate heat back into the room, further increasing your living comfort. Metal & Steel Buildings. Temperature sensitive storage areas. Wrapping Chocolates, Candy and Food for freshness. Silver foil Bubble Wrap. Insulation applications are only limited by your imagination. CSIRO- Materials Science & Engineering. (ABN: 41 687 119 230). Page 1 of 1. Sample Description: silver insulation material designed for pallet protection. At an ambient temperature of 23.1ºC – difference from face to back 2.4ºC. At an ambient temperature of 28.6ºC – difference from face to back 5.1ºC. OF THE INSULATIVE EFFECTIVENESS OF SINGLE-SIDED 10 MILLIMETRE BUBBLE FILM (4.8 mm Thick). LAMINATED WITH METALLISED P. The above test report conducted by the CSIRO relates only to the single foil insulation. The double foil provides even more superior features and a higher r value. The main feature of this insulation is its reflective nature and not the thickness of the material. It has a nominal thickness of 4.8 mm and easy to handle. We can also custom make any combination to suit your requirements. You can have foam sandwiched between two layers of Silver foil, Or thicker bubbles between tow layers of foil, or any combination you require. Please note custom made insulation attracts minimum order of 1,500 Square meters. Custom orders are final. All the insulation is made right here in Australia with the highest standard of material and manufacture. This is a high quality industrial strength Foil Bubble Wrap. Long lasting, heavy duty nylon barrier layer to increase longevity. Bubble Wrap is Lightweight and easy to use. It is an inexpensive solution to your insulation needs. THE TRUTH ABOUT R VALUE. Around most of the world, R-values are given in SI units, typically square-metre kelvin per watt or m2·K/W (or equally, m2·°C/W). In the United States customary units, R-values are given in units of ft2·°F·hr/Btu. It is particularly easy to confuse SI and US R-values, because R-values both in the US and elsewhere are often cited without their units, e. Usually, however, the correct units can be inferred from the context and from the magnitudes of the values. United States R-values are approximately six times SI R-values. The conversion between SI and US units of R-value is 1 h·ft2·°F/Btu = 0.176110 K·m2/W, or 1 K·m2/W = 5.678263 h·ft2·°F/Btu. As an example an R11 in the United States is approximately R2 in SI units in Europe, Australia and the rest of the world. An R value advertised by a United States merchant may appear more appealing as the US R value is 6 times higher than SI values used in the rest of the world. It does not mean that a US R value is more effective than An R value used in Europe, Australia or the rest of the world. Do not rely on the R value provided by the supplier as the R value may increase or decrease depending on the application. Furthermore, the actual R value of the insulation depends entirely on the application and how you apply the insulation. An R 2 value may increase or decrease depending on how the insulation is applied. With the Silver Foil bubble Insulation you will need an air pocket between the surface of the structure you are insulating and the insulation material. The air pocket has its own r value depending on the width of the air pocket thus increasing the R value of the insulation material. Conversely, if you apply the insulation material directly on the surface of the structure will defeat the purpose of insulation because the insulation material will act as a heat conductor and will end up heating the premises in the hot summer and will also be counterproductive in winter. Radiation is minimized by low emissivity (highly reflective) exterior surfaces such as aluminum foil. Lower thermal conductivity, or higher R-values, can be achieved by allowing an air gap between the surface of the structure and the aluminium foil. The air gap will act an heat pocket where heat will accumulate instead of being circulation inside your structure. Trapped air has its own R value. The R value of trapped air depends on how much gap is between the insulation material an the structure. A wider gap will produce a greater R value and a narrower gap will produce a smaller R value. Air by itself has no R value; only trapped air will produce an R value. However, if you allow a very wide gap, the air will not be trapped and may reduce your R value and cause an opposite result. The R-value is a measure of an insulation sample’s ability to reduce the rate of heat flow under specified test conditions. The primary mode of heat transfer impeded by insulation is conduction, but insulation also reduces heat loss by all three heat transfer modes: conduction, convection, and radiation. The primary means of heat loss across an uninsulated air-filled space is natural convection, which occurs because of changes in air density with temperature. Insulation greatly retards natural convection making the primary mode of heat transfer conduction. To find the heat loss per square meter, simply divide the temperature difference by the R value. If the interior of a home is at 20 °C, and the roof cavity is at 10 °C, the temperature difference is 10 C° (= 10 K difference). Assuming a ceiling insulated to R-2 (R = 2.0 m2K/W), energy will be lost at a rate of 10 K/2 K·m2/W = 5 watts for every square meter of ceiling. Doubling the thickness of the insulation material or even doubling the thickness of the trapped air layer doubles the R value. This does not hold for compressed bats of glass wool because compressing the bats does not proportionally increase the r value. Furthermore, doubling the thickness of the Silver Foil Bubble Insulation does not double the R value of the insulation material. The main feature of the Silver Backed Bubble Insulation is its reflective nature and not its thickness. To Double the R value of the Foil Bubble Insulation you will need to create a heat pocket which hads it s own R value that can be added to the R value of the Foil Insulation. As an example, the if Foil Bubble Insulation has an R value of r2 and the heat pocket has an R value of R 1,5, both R value are added together to achieve an R value of R3.5 in SI units or R19 in United States standards. As discussed earlier porous material such as foam and bats does not allow the full potential of trapped air to be established and will not give you the proportional R value relative to thickness. In calculating the R-value of a multi-layered installation, the R-values of the individual layers are added:[10]. R-value(outside air film) + R-value(brick) + R-value(sheathing) + R-value(insulation) + R-value(plasterboard) + R-value(inside air film) = R-value(total). To account for other components in a wall such as framing, an area-weighted average R-value of the whole wall may be calculated. For the most part, testing the R-value of insulation is done at a steady temperature, usually about 70 °F (21 °C) with no surrounding air movement. Since these are ideal conditions, the listed R-value for insulation will almost certainly be higher than it would be in actual use, because most situations with insulation are under different conditions. Some types of foam insulation, such as polyurethane and polyisocyanurate are blown with heavy gases such as chlorofluorocarbons (CFC) or hydrochlorofluorocarbons (HFCs). However, over time a small amount of these gases diffuse out of the foam and are replaced by air, thus reducing the effective R-value of the product. This has led to controversy as how to rate the insulation of these products. Many manufacturers will rate the R-value at the time of manufacture; critics argue that a more fair assessment would be its settled value. [citation needed] The foam industrywhen? Adopted the LTTR (Long-Term Thermal Resistance) method, [14] which rates the R-value based on a 15 year weighted average. However, the LTTR effectively provides only an eight-year aged R-value, short in the scale of a building that may have a lifespan of 50 to 100 years. Note that these examples use the non-SI definition and/or given for a 1 inch (25.4 mm) thick sample. Vacuum insulated panels have the highest R-value (approximately R-45 per inch in American customary units); aerogel has the next highest R-value (about R-10-30 per inch), followed by isocyanurate and phenolic foam insulations with, R-8.3 and R-7 per inch, respectively. They are followed closely by polyurethane and polystyrene insulation at roughly R-6 and R-5 per inch. Loose cellulose, fiberglass (both blown and in batts), and rock wool (both blown and in batts) all possess an R-value of roughly R–2.5 to R–4 per inch. Straw bales perform at about R-1.5. However, typical straw bale houses have very thick walls and thus are well insulated. Snow is roughly R-1. The effective thermal resistance of an enclosed air cavity is strongly influenced by radiative heat transfer and distance between the two surfaces. All quality products at bargain prices. Occasionally, I list the same item with discounted prices for a limited time. Please Note: This insulation comes in 50 meter long rolls. This may come in one or multiple rolls totalling 40 meters. Public holidays and weekends excluded. However, there is no guarantee that you will receive your parcel by the estimated date. The most economical method. If you wish to have your item delivered or handled in a special manner, let me know and I will inform you if there is any additional charge. If you live in a remote location with no courier service, let me know. Delays may be experienced in case of work overload, postal or courier. Delays, public holidays and weekends, or shortage of stock. If premises unattended, leave in a secure location. If premises unattended, place a card in the mailbox and leave parcel at nearest collection point. The parcel shall be deemed to have been delivered. If the parcel is sent by courier, a signature is usually required. You can select that the courier leaves the parcel. If it is not safe to leave the parcel by Your front door, then you will need to sign for it. All parcels will be securely packaged. For its loss or damage. Otherwords, all care taken and no responsibility accepted. No responsibility can be taken if you fail to provide a telephone number. Please note, I assume no responsibility if the item is delayed, lost or damaged n transit. No compensation will be paid until such investigation has been concluded. You will also need to arrange for your own packaging. International Buyers – Please Note. I strive to please my fellow eBayers. If you have any issue with the item, let me know. Errors & Omissions Excluded. No other warranties either expressed or implied are offered. You may find similar items cheaper with other sellers or retailers. I also rely on sighted assistants to help with the pictures and description. If you prefer to trade with a behemoth, please go elsewhere. From time to time I offer the same item cheaper for a limited period. The description of the items is as provided by the principal sellers and believed to be reliable. All feedback will be reciprocated. If you are happy with my service, tell the whole world, if you are not happy, tell me. If you have any issue with the item, contact me first before you post negative or neutral feedback. Issues can be resolved amicably. Leaving damaging feedback before your attempt to resolve any issue first will be deemed as defamatory and in contravention of the terms and conditions and will be dealt with accordingly. The bad Karma will result in proceedings for the removal of such feedback and will give rise of a liquidated claim for damages. Any unwarranted negative or neutral feedback will be removed using legal processes and may give rise to a liquidated claim for defamation or/ and breach of contract. All issues can be resolved amicably. An issue, contact me first. If you have any issues with your item, let me know and I will be happy to rectify any problem. If you post negative or neutral feedback without first letting me know of your intention to post such feedback will be deemed defamatory and may give rise to proceedings for defamation and/or breach of contract and will give rise to a liquidated claim for damages. If you have in issue, it would be quicker to contact me first and I will do my utmost to help you. If you do not wish to have feedback posted for you – for privacy reasons or otherwise – just let me know and I will not post feedback for you or simply do not post feedback for me. All brand names & trademarks are the property of their respective holders and are referred to here for descriptive purpose only. The listed brand names and model designations are intended only to show the compatibility of these products with various products. Pictures are for descriptive purposes only. All dimensions and measurements are approximate. Colour is as shown unless otherwise stated. Colour may vary depending on lighting, your computer screen resolution or angle of viewing. Please exercise care when you open your package when you receive it. Do not slash the packing material with a knife as to damage the contents of the package. Open carefully so you don’t drop the contents in case of fragile or breakable items. If the information is not correct, please provide your correct contact information. You agree to abide by the herein Terms & Conditions and any further amendments. Any dispute arising out of this. Agreement or the interpretation thereof. Shall be decided and. Settled in accordance with the laws and statues of the State of New South Wales, Australia. The parties agree that the venue shall be Sydney, New south Wales. Be sure to add me to your. Track Page Views With. Auctiva’s FREE Counter. This item is in the category “Industrial\Building Materials\Insulation & Accessories\Insulation”. The seller is “eddiesolomon777″ and is located in this country: AU. This item can be shipped worldwide.
  • Custom Bundle: No
  • Material: Foil backed bubble wrap
  • Type: Foil Bubble Insulation
  • Features: Heat Retardant
  • Insulation R-Value: R2
  • MPN: SFBI1
  • Model: Single Sided Foil
  • Modified Item: No
  • Product Type: Insulation
  • Packaging: Roll
  • Brand: INSULATION ACADEMY
  • Suitable For: Caravan, Campervan, Truck, Keep Food Fresh, Dog House, Attic/Loft, Basement, Ceiling, Floor, Garage, Interior Wall
  • UPC: 0602401607958

Silver Foil Cell Air Bubble Insulation 30 Sqm 750mm W Australian Csiro Tested

Heavy Duty Thick Double Foil Air Bubbl Cell Insulation 40 Sqm Australia Made

Posted on by
Heavy_Duty_Thick_Double_Foil_Air_Bubbl_Cell_Insulation_40_Sqm_Australia_Made_01_sduf Heavy Duty Thick Double Foil Air Bubbl Cell Insulation 40 Sqm Australia Made
Heavy Duty Thick Double Foil Air Bubbl Cell Insulation 40 Sqm Australia Made
Heavy Duty Thick Double Foil Air Bubbl Cell Insulation 40 Sqm Australia Made
Heavy Duty Thick Double Foil Air Bubbl Cell Insulation 40 Sqm Australia Made
Heavy Duty Thick Double Foil Air Bubbl Cell Insulation 40 Sqm Australia Made
Heavy Duty Thick Double Foil Air Bubbl Cell Insulation 40 Sqm Australia Made

Heavy Duty Thick Double Foil Air Bubbl Cell Insulation 40 Sqm Australia Made
Thank you for viewing my listing. DOUBLE SIDED SILVER FOIL. TWO LAYERS OF FOIL. REDUCE RADIANT HEAT TRANSFER. IDEAL FOR HOT OR COLD CLIMATE. 40 SQUARE METERS (440 SQUARE FEET). 20 MM (3/4) DIAMETER BUBBLES. 8 MM THICK (3/8) BUBBLES. TWO LAYERS OF ALUMINUM FOIL. Call Eddie Solomon if you have any question. Please Note: this product does not comply with Australian Standards nor the Building Code but it is tested by Australian CSIRO and has been used widely for home insulation. SILVER FOIL BUBBLE INSULATION. Double Foil Insulation is available in 75 Square Meters rolls – 1,500 mm wide x 50 Meters long. It consists of a layer of polyethylene bubbles that is sandwiched between two layers of 99% pure aluminum radiant barrier foil. This style can be used in a variety of applications because it’s light weight and easy to handle yet provides superior protection. The bubble center creates maximum R-Value and the reflective foil on both sides allow it to reflect 97% of radiant heat away from a structure on the outside and back in on a structure from the inside. This is why it works effectively in both hot and cold climates. Double Foil Reflective Insulation is a versatile insulation consisting of an 4.8 mm thick – 10 mm diameter layer of polyethylene bubbles sandwiched between two sheets of highly reflective, 99% aluminum. Reflective Bubble Insulation provides superior reflectivity of radiant heat while providing protection against conductive heat gain and loss as well as performing as a vapor barrier. Nominal Thickness 1/4 – 0.6 mm. Weight 0.5 oz / sq. Ft – 160 g/sq m. Temperature Range – ASTM C411 -50 F to 180 F (-45 c to 82 c). Flame Spread (ASTM E84-05) 5. Smoke Development (ASTM E84-05) 5. Emissivity – ASTM C1371 0.03-0.04. Reflectivity – ASTM 3903 0.96-0.97. Water Vapor Permeance-ASTM E96. Flexibility – No Cracking. Resistant to Fungi and Bacteria Does not promote growth. ADVANTAGES OF THIS PRODUCT. Very effective in warmer climates. No change to thermal performance over time due to compaction, disintegration or moisture absorption. Thin sheets takes up less room than bulk insulation. Can act as a vapor barrier. Will not mold or mildew. Radon retarder, will limit radon penetration through the floor. This is a high quality industrial strength Double Foil Insulation Bubble Wrap. Long lasting, heavy duty nylon barrier layer to increase longevity. Bubble Wrap is Lightweight and easy to use. It is an inexpensive solution to your insulation needs. This 75 Square meter Silver Insulation Foil Bubble Wrap usually comes in rolls of 1,500 mm wide. However, it may come in other widths totalling 75 Square meter depending on availability. Our standard single and double bubble foil insulation is. Silver foil Available in a range of widths, from. 375 mm 15″ to 1,500 mm (60″), and lengths. We offer double-sided Silver. Aluminium products, as well as products covered with Silver Foil. On one side and white polyethylene on the other. This durable bubble insulation will withstand temperatures between -50 degrees Celsius. And 82 degrees Celsius (180 degrees Fahrenheit), making it ideal for both attic and flooring installations. Be sure to check out our silver Foil Aluminium. This is the best tape for bubble foil insulation because it ensures the continuity of the reflective surface, which is essential for getting the most from your installation. Radiant floor heating has been in use for centuries and radiant barriers help to retain the heat generated by the radiant heating system blocking it from escaping into the ground. Silver foil bubble Wrap. Insulation is extremely tough and pliable, easy to install, and is an excellent vapor barrier for all your radiant floor heating applications, thus greatly reducing your electricity or gas bills. Silver Foil Bubble wrap. Insulation installed in crawl spaces below a building structure reflect the heat flows that are flowing downward from the flooring back up into the flooring at a 95-97% rate providing increased comfort and heat retention. The temperature of the cold floors which cause cold feet will be raised while your heating bill is reduced, providing for increased comfort. As heat is reflected back into the living area, it warms other objects which then radiate heat back into the room, further increasing your living comfort. Metal & Steel Buildings. Temperature sensitive storage areas. Silver foil Bubble Wrap. Insulation applications are only limited by your imagination. The main feature of this insulation is its reflective nature and not the thickness of the material. It has a nominal thickness of 4.8 mm and easy to handle. We can also custom make any combination to suit your requirements. You can have foam sandwiched between two layers of Silver foil, Or thicker bubbles between tow layers of foil, or any combination you require. Please note custom made insulation attracts minimum order of 1,500 Square meters. Custom orders are final. All the insulation is made right here in Australia with the highest standard of material and manufacture. The following Test Report conducted by the Australian CSIRO on the single Foil Bubble Insulation. This listing is for the Double Foil Bubble Insulation which commands a higher insulation quality tham the single. CSIRO- Materials Science & Engineering. Page 1 of 1. Sample Description: silver insulation material designed for pallet protection. At an ambient temperature of 23.1ºC – difference from face to back 2.4ºC. At an ambient temperature of 28.6ºC – difference from face to back 5.1ºC. OF THE INSULATIVE EFFECTIVENESS OF SINGLE-SIDED 10 MILLIMETRE BUBBLE FILM (4.8 mm Thick). LAMINATED WITH METALLISED P. THE TRUTH ABOUT R VALUE. Around most of the world, R-values are given in SI units, typically square-metre kelvin per watt or m2·K/W (or equally, m2·°C/W). In the United States customary units, R-values are given in units of ft2·°F·hr/Btu. It is particularly easy to confuse SI and US R-values, because R-values both in the US and elsewhere are often cited without their units, e. Usually, however, the correct units can be inferred from the context and from the magnitudes of the values. United States R-values are approximately six times SI R-values. The conversion between SI and US units of R-value is 1 h·ft2·°F/Btu = 0.176110 K·m2/W, or 1 K·m2/W = 5.678263 h·ft2·°F/Btu. As an example an R11 in the United States is approximately R2 in SI units in Europe, Australia and the rest of the world. An R value advertised by a United States merchant may appear more appealing as the US R value is 6 times higher than SI values used in the rest of the world. It does not mean that a US R value is more effective than An R value used in Europe, Australia or the rest of the world. Do not rely on the R value provided by the supplier as the R value may increase or decrease depending on the application. Furthermore, the actual R value of the insulation depends entirely on the application and how you apply the insulation. An R 2 value may increase or decrease depending on how the insulation is applied. With the Silver Foil bubble Insulation you will need an air pocket between the surface. Of the structure you are insulating. And the insulation material. The air pocket has its own r value depending on the width of the air pocket thus increasing the R value of the insulation material. Conversely, if you apply the insulation material directly on the surface of the structure will defeat the purpose of insulation because the insulation material will act as a heat conductor and will end up heating the premises in the hot summer and will also be counterproductive in winter. Radiation is minimized by low emissivity (highly reflective) exterior surfaces such as aluminum foil. Lower thermal conductivity, or higher R-values, can be achieved by allowing an air gap between the surface of the structure and the aluminium foil. The air gap will act an heat pocket where heat will accumulate instead of being circulation inside your structure. Trapped air has its own R value. The R value of trapped air depends on how much gap is between the insulation material an the structure. A wider gap will produce a greater R value and a narrower. Gap will produce a smaller R value. Air by itself has no R value; only trapped air will produce an R value. However, if you allow a very wide gap, the air will not be trapped and may reduce your R value and cause an opposite result. The R-value is a measure of an insulation sample’s ability to reduce the rate of heat flow under specified test conditions. The primary mode of heat transfer impeded by insulation is conduction, but insulation also reduces heat loss by all three heat transfer modes: conduction, convection, and radiation. The primary means of heat loss across an uninsulated air-filled space is natural convection, which occurs because of changes in air density with temperature. Insulation greatly retards natural convection making the primary mode of heat transfer conduction. To find the heat loss per square meter, simply divide the temperature difference by the R value. If the interior of a home is at 20 °C, and the roof cavity is at 10 °C, the temperature difference is 10 C° (= 10 K difference). Assuming a ceiling insulated to R-2 (R = 2.0 m2K/W), energy will be lost at a rate of 10 K/2 K·m2/W = 5 watts for every square meter of ceiling. Doubling the thickness of the insulation material or even doubling the thickness of the trapped air layer doubles the R value. This does not hold for compressed bats of glass wool because compressing the bats does not proportionally increase the r value. Furthermore, doubling the thickness of the Silver Foil Bubble Insulation does not double the R value of the insulation material. The main feature of the Silver Backed Bubble Insulation is its reflective nature and not its thickness. To Double the R value of the Foil Bubble Insulation you will need to create a heat pocket which hads it s own R value that can be added to the R value of the Foil Insulation. As an example, the if Foil Bubble Insulation has an R value of r2 and the. Heat pocket has an R value of R 1,5, both R value are added together to achieve an R value of R3.5 in SI units or R19 in United States standards. As discussed earlier porous material such as foam and bats does not allow the full potential of trapped air to be established and will not give you the proportional R value relative to thickness. In calculating the R-value of a multi-layered installation, the R-values of the individual layers are added:[10]. R-value(outside air film) + R-value(brick) + R-value(sheathing) + R-value(insulation) + R-value(plasterboard) + R-value(inside air film) = R-value(total). To account for other components in a wall such as framing, an area-weighted average R-value of the whole wall may be calculated. For the most part, testing the R-value of insulation is done at a steady temperature, usually about 70 °F (21 °C) with no surrounding air movement. Since these are ideal conditions, the listed R-value for insulation will almost certainly be higher than it would be in actual use, because most situations with insulation are under different conditions. Some types of foam insulation, such as polyurethane and polyisocyanurate are blown with heavy gases such as chlorofluorocarbons (CFC) or hydrochlorofluorocarbons (HFCs). However, over time a small amount of these gases diffuse out of the foam and are replaced by air, thus reducing the effective R-value of the product. This has led to controversy as how to rate the insulation of these products. Many manufacturers will rate the R-value at the time of manufacture; critics argue that a more fair assessment would be its settled value. [citation needed] The foam industrywhen? Adopted the LTTR (Long-Term Thermal Resistance) method, [14] which rates the R-value based on a 15 year weighted average. However, the LTTR effectively provides only an eight-year aged R-value, short in the scale of a building that may have a lifespan of 50 to 100 years. Note that these examples use the non-SI definition and/or given for a 1 inch (25.4 mm) thick sample. Vacuum insulated panels have the highest R-value (approximately R-45 per inch in American customary units); aerogel has the next highest R-value (about R-10-30 per inch), followed by isocyanurate and phenolic foam insulations with, R-8.3 and R-7 per inch, respectively. They are followed closely by polyurethane and polystyrene insulation at roughly R-6 and R-5 per inch. Loose cellulose, fiberglass (both blown and in batts), and rock wool (both blown and in batts) all possess an R-value of roughly R–2.5 to R–4 per inch. Straw bales perform at about R-1.5. However, typical straw bale houses have very thick walls and thus are well insulated. Snow is roughly R-1. The effective thermal resistance of an enclosed air cavity is strongly influenced by radiative heat transfer and distance between the two surfaces. All quality products at bargain prices. Occasionally, I list the same item with discounted prices for a limited time. Please Note: Due to the bulky size of this insulation, the 75 Square Meters are sent as follows. 1 Roll of 75 square meters – 1,500 mm wide 50 m long. 2 Rolls of 37.5 Square meters – 1,500 mm wide 25 m long each. 2 rolls of 37.5 Square meters each – 750 mm wide 50 m long. Public holidays and weekends excluded. However, there is no guarantee that you will receive your parcel by the estimated date. The most economical method. If you wish to have your item delivered or handled in a special manner, let me know and I will inform you if there is any additional charge. If you live in a remote location with no courier service, let me know. Delays may be experienced in case of work overload, postal or courier. Delays, public holidays and weekends, or shortage of stock. If premises unattended, leave in a secure location. If premises unattended, place a card in the mailbox and leave parcel at nearest collection point. The parcel shall be deemed to have been delivered. If the parcel is sent by courier, a signature is usually required. You can select that the courier leaves the parcel. If it is not safe to leave the parcel by Your front door, then you will need to sign for it. All parcels will be securely packaged. For its loss or damage. Otherwords, all care taken and no responsibility accepted. No responsibility can be taken if you fail to provide a telephone number. Please note, I assume no responsibility if the item is delayed, lost or damaged n transit. No compensation will be paid until such investigation has been concluded. You will also need to arrange for your own packaging. International Buyers – Please Note. I strive to please my fellow eBayers. If you have any issue with the item, let me know. Errors & Omissions Excluded. No other warranties either expressed or implied are offered. You may find similar items cheaper with other sellers or retailers. I also rely on sighted assistants to help with the pictures and description. If you prefer to trade with a behemoth, please go elsewhere. From time to time I offer the same item cheaper for a limited period. The description of the items is as provided by the principal sellers and believed to be reliable. All feedback will be reciprocated. If you are happy with my service, tell the whole world, if you are not happy, tell me. If you have any issue with the item, contact me first before you post negative or neutral feedback. Issues can be resolved amicably. Leaving damaging feedback before your attempt to resolve any issue first will be deemed as defamatory and in contravention of the terms and conditions and will be dealt with accordingly. The bad Karma will result in proceedings for the removal of such feedback and will give rise of a liquidated claim for damages. Any unwarranted negative or neutral feedback will be removed using legal processes and may give rise to a liquidated claim for defamation or/ and breach of contract. All issues can be resolved amicably. An issue, contact me first. If you have any issues with your item, let me know and I will be happy to rectify any problem. If you post negative or neutral feedback without first letting me know of your intention to post such feedback will be deemed defamatory and may give rise to proceedings for defamation and/or breach of contract and will give rise to a liquidated claim for damages. If you have in issue, it would be quicker to contact me first and I will do my utmost to help you. If you do not wish to have feedback posted for you – for privacy reasons or otherwise – just let me know and I will not post feedback for you or simply do not post feedback for me. All brand names & trademarks are the property of their respective holders and are referred to here for descriptive purpose only. The listed brand names and model designations are intended only to show the compatibility of these products with various products. Pictures are for descriptive purposes only. All dimensions and measurements are approximate. Colour is as shown unless otherwise stated. Colour may vary depending on lighting, your computer screen resolution or angle of viewing. Please exercise care when you open your package when you receive it. Do not slash the packing material with a knife as to damage the contents of the package. Open carefully so you don’t drop the contents in case of fragile or breakable items. If the information is not correct, please provide your correct contact information. You agree to abide by the herein Terms & Conditions and any further amendments. Any dispute arising out of this. Agreement or the interpretation thereof. Shall be decided and. Settled in accordance with the laws and statues of the State of New South Wales, Australia. The parties agree that the venue shall be Sydney, New south Wales. This item is in the category “Home & Garden\Other Home & Garden”. The seller is “eddiesolomon777″ and is located in this country: AU. This item can be shipped worldwide.
  • Product Type: Silver Foil Bubble Wrap Insulation
  • Modified Item: No
  • Style: Double Sided Foil
  • Custom Bundle: No
  • Type: Roll
  • MPN: SFBI2
  • Brand: EDDIE SOLOMON
  • UPC: 722197213819

Heavy Duty Thick Double Foil Air Bubbl Cell Insulation 40 Sqm Australia Made

Thick Heavy Duty Double Foil Air Bubble Cell Insulation 75 Sqm Large Bubbles

Posted on by
Thick_Heavy_Duty_Double_Foil_Air_Bubble_Cell_Insulation_75_Sqm_Large_Bubbles_01_lyir Thick Heavy Duty Double Foil Air Bubble Cell Insulation 75 Sqm Large Bubbles
Thick Heavy Duty Double Foil Air Bubble Cell Insulation 75 Sqm Large Bubbles
Thick Heavy Duty Double Foil Air Bubble Cell Insulation 75 Sqm Large Bubbles
Thick Heavy Duty Double Foil Air Bubble Cell Insulation 75 Sqm Large Bubbles
Thick Heavy Duty Double Foil Air Bubble Cell Insulation 75 Sqm Large Bubbles
Thick Heavy Duty Double Foil Air Bubble Cell Insulation 75 Sqm Large Bubbles
Thick Heavy Duty Double Foil Air Bubble Cell Insulation 75 Sqm Large Bubbles
Thick Heavy Duty Double Foil Air Bubble Cell Insulation 75 Sqm Large Bubbles
Thick Heavy Duty Double Foil Air Bubble Cell Insulation 75 Sqm Large Bubbles

Thick Heavy Duty Double Foil Air Bubble Cell Insulation 75 Sqm Large Bubbles
Thank you for viewing my listing. DOUBLE SIDED SILVER FOIL. TWO LAYERS OF FOIL. REDUCE RADIANT HEAT TRANSFER. IDEAL FOR HOT OR COLD CLIMATE. 75 SQUARE METERS (825 SQUARE FEET). 20 MM (3/4) DIAMETER BUBBLES. TWO LAYERS OF ALUMINUM FOIL. THIS IS THE THICK – 20 MM DIAMETER BUBBLES FOR EXTRA PROTECTION. THE LARGE 20MM DIAMETER AIR BUBBLES PROVIDE EXTRA INSULATION PROPERTIES. THE 20MM DIAMETER IS NOT THE THICKNESS OF THE INSULATION, IT IS THE LARGER BUBBLES. Call Eddie Solomon if you have any question. Please Note: this product does not comply with Australian Standards nor the Building Code but it is tested by Australian CSIRO and has been used widely for home insulation. TO VIEW ALL FOIL BUBBLE INSULATION. SILVER FOIL BUBBLE INSULATION. Double Foil Insulation is available in 75 Square Meters rolls – 1,500 mm wide x 50 Meters long. It consists of a layer of polyethylene bubbles that is sandwiched between two layers of 99% pure aluminum radiant barrier foil. This style can be used in a variety of applications because it’s light weight and easy to handle yet provides superior protection. The bubble center creates maximum R-Value and the reflective foil on both sides allow it to reflect 97% of radiant heat away from a structure on the outside and back in on a structure from the inside. This is why it works effectively in both hot and cold climates. Double Foil Reflective Insulation is a versatile insulation consisting of a – 20 mm diameter layer of polyethylene bubbles sandwiched between two sheets of highly reflective, 99% aluminum. Reflective Bubble Insulation provides superior reflectivity of radiant heat while providing protection against conductive heat gain and loss as well as performing as a vapor barrier. Nominal Thickness 1/4 – 0.6 mm. Weight 0.5 oz / sq. Ft – 160 g/sq m. Temperature Range – ASTM C411 -50 F to 180 F (-45 c to 82 c). Flame Spread (ASTM E84-05) 5. Smoke Development (ASTM E84-05) 5. Emissivity – ASTM C1371 0.03-0.04. Reflectivity – ASTM 3903 0.96-0.97. Water Vapor Permeance-ASTM E96. Flexibility – No Cracking. Resistant to Fungi and Bacteria Does not promote growth. ADVANTAGES OF THIS PRODUCT. Very effective in warmer climates. No change to thermal performance over time due to compaction, disintegration or moisture absorption. Thin sheets takes up less room than bulk insulation. Can act as a vapor barrier. Will not mold or mildew. Radon retarder, will limit radon penetration through the floor. This is a high quality industrial strength Double Foil Insulation Bubble Wrap. Long lasting, heavy duty nylon barrier layer to increase longevity. Bubble Wrap is Lightweight and easy to use. It is an inexpensive solution to your insulation needs. This 75 Square meter Silver Insulation Foil Bubble Wrap usually comes in rolls of 1,500 mm wide. However, it may come in other widths totalling 75 Square meter depending on availability. Our standard single and double bubble foil insulation is. Silver foil Available in a range of widths, from. 375 mm 15″ to 1,500 mm (60″), and lengths. We offer double-sided Silver. Aluminium products, as well as products covered with Silver Foil. On one side and white polyethylene on the other. This durable bubble insulation will withstand temperatures between -50 degrees Celsius. And 82 degrees Celsius (180 degrees Fahrenheit), making it ideal for both attic and flooring installations. Be sure to check out our silver Foil Aluminium. This is the best tape for bubble foil insulation because it ensures the continuity of the reflective surface, which is essential for getting the most from your installation. Radiant floor heating has been in use for centuries and radiant barriers help to retain the heat generated by the radiant heating system blocking it from escaping into the ground. Silver foil bubble Wrap. Insulation is extremely tough and pliable, easy to install, and is an excellent vapor barrier for all your radiant floor heating applications, thus greatly reducing your electricity or gas bills. Silver Foil Bubble wrap. Insulation installed in crawl spaces below a building structure reflect the heat flows that are flowing downward from the flooring back up into the flooring at a 95-97% rate providing increased comfort and heat retention. The temperature of the cold floors which cause cold feet will be raised while your heating bill is reduced, providing for increased comfort. As heat is reflected back into the living area, it warms other objects which then radiate heat back into the room, further increasing your living comfort. Metal & Steel Buildings. Temperature sensitive storage areas. Silver foil Bubble Wrap. Insulation applications are only limited by your imagination. The main feature of this insulation is its reflective nature and not the thickness of the material. We can also custom make any combination. To suit your requirements. You can have foam sandwiched between two layers of Silver foil, Or thicker bubbles between tow layers of foil, or any combination you require. Please note custom made insulation attracts minimum order of 1,500 Square meters. Custom orders are final. All the insulation is made right here in Australia with the highest standard of material and manufacture. The following Test Report conducted by the Australian CSIRO on the single Foil Bubble Insulation. This listing is for the Double Foil Bubble Insulation which commands a higher insulation quality tham the single. CSIRO- Materials Science & Engineering. Page 1 of 1. Sample Description: silver insulation material designed for pallet protection. At an ambient temperature of 23.1ºC – difference from face to back 2.4ºC. At an ambient temperature of 28.6ºC – difference from face to back 5.1ºC. OF THE INSULATIVE EFFECTIVENESS OF SINGLE-SIDED 10 MILLIMETRE BUBBLE FILM. LAMINATED WITH METALLISED P. THE TRUTH ABOUT R VALUE. Around most of the world, R-values are given in SI units, typically square-metre kelvin per watt or m2·K/W (or equally, m2·°C/W). In the United States customary units, R-values are given in units of ft2·°F·hr/Btu. It is particularly easy to confuse SI and US R-values, because R-values both in the US and elsewhere are often cited without their units, e. Usually, however, the correct units can be inferred from the context and from the magnitudes of the values. United States R-values are approximately six times SI R-values. The conversion between SI and US units of R-value is 1 h·ft2·°F/Btu = 0.176110 K·m2/W, or 1 K·m2/W = 5.678263 h·ft2·°F/Btu. As an example an R11 in the United States is approximately R2 in SI units in Europe, Australia and the rest of the world. An R value advertised by a United States merchant may appear more appealing as the US R value is 6 times higher than SI values used in the rest of the world. It does not mean that a US R value is more effective than An R value used in Europe, Australia or the rest of the world. Do not rely on the R value provided by the supplier as the R value may increase or decrease depending on the application. Furthermore, the actual R value of the insulation depends entirely on the application and how you apply the insulation. An R 2 value may increase or decrease depending on how the insulation is applied. With the Silver Foil bubble Insulation you will need an air pocket between the surface. Of the structure you are insulating. And the insulation material. The air pocket has its own r value depending on the width of the air pocket thus increasing the R value of the insulation material. Conversely, if you apply the insulation material directly on the surface of the structure will defeat the purpose of insulation because the insulation material will act as a heat conductor and will end up heating the premises in the hot summer and will also be counterproductive in winter. Radiation is minimized by low emissivity (highly reflective) exterior surfaces such as aluminum foil. Lower thermal conductivity, or higher R-values, can be achieved by allowing an air gap between the surface of the structure and the aluminium foil. The air gap will act an heat pocket where heat will accumulate instead of being circulation inside your structure. Trapped air has its own R value. The R value of trapped air depends on how much gap is between the insulation material an the structure. A wider gap will produce a greater R value and a narrower. Gap will produce a smaller R value. Air by itself has no R value; only trapped air will produce an R value. However, if you allow a very wide gap, the air will not be trapped and may reduce your R value and cause an opposite result. The R-value is a measure of an insulation sample’s ability to reduce the rate of heat flow under specified test conditions. The primary mode of heat transfer impeded by insulation is conduction, but insulation also reduces heat loss by all three heat transfer modes: conduction, convection, and radiation. The primary means of heat loss across an uninsulated air-filled space is natural convection, which occurs because of changes in air density with temperature. Insulation greatly retards natural convection making the primary mode of heat transfer conduction. To find the heat loss per square meter, simply divide the temperature difference by the R value. If the interior of a home is at 20 °C, and the roof cavity is at 10 °C, the temperature difference is 10 C° (= 10 K difference). Assuming a ceiling insulated to R-2 (R = 2.0 m2K/W), energy will be lost at a rate of 10 K/2 K·m2/W = 5 watts for every square meter of ceiling. Doubling the thickness of the insulation material or even doubling the thickness of the trapped air layer doubles the R value. This does not hold for compressed bats of glass wool because compressing the bats does not proportionally increase the r value. Furthermore, doubling the thickness of the Silver Foil Bubble Insulation does not double the R value of the insulation material. The main feature of the Silver Backed Bubble Insulation is its reflective nature and not its thickness. To Double the R value of the Foil Bubble Insulation you will need to create a heat pocket which hads it s own R value that can be added to the R value of the Foil Insulation. As an example, the if Foil Bubble Insulation has an R value of r2 and the. Heat pocket has an R value of R 1,5, both R value are added together to achieve an R value of R3.5 in SI units or R19 in United States standards. As discussed earlier porous material such as foam and bats does not allow the full potential of trapped air to be established and will not give you the proportional R value relative to thickness. In calculating the R-value of a multi-layered installation, the R-values of the individual layers are added:[10]. R-value(outside air film) + R-value(brick) + R-value(sheathing) + R-value(insulation) + R-value(plasterboard) + R-value(inside air film) = R-value(total). To account for other components in a wall such as framing, an area-weighted average R-value of the whole wall may be calculated. For the most part, testing the R-value of insulation is done at a steady temperature, usually about 70 °F (21 °C) with no surrounding air movement. Since these are ideal conditions, the listed R-value for insulation will almost certainly be higher than it would be in actual use, because most situations with insulation are under different conditions. Some types of foam insulation, such as polyurethane and polyisocyanurate are blown with heavy gases such as chlorofluorocarbons (CFC) or hydrochlorofluorocarbons (HFCs). However, over time a small amount of these gases diffuse out of the foam and are replaced by air, thus reducing the effective R-value of the product. This has led to controversy as how to rate the insulation of these products. Many manufacturers will rate the R-value at the time of manufacture; critics argue that a more fair assessment would be its settled value. [citation needed] The foam industrywhen? Adopted the LTTR (Long-Term Thermal Resistance) method, [14] which rates the R-value based on a 15 year weighted average. However, the LTTR effectively provides only an eight-year aged R-value, short in the scale of a building that may have a lifespan of 50 to 100 years. Note that these examples use the non-SI definition and/or given for a 1 inch (25.4 mm) thick sample. Vacuum insulated panels have the highest R-value (approximately R-45 per inch in American customary units); aerogel has the next highest R-value (about R-10-30 per inch), followed by isocyanurate and phenolic foam insulations with, R-8.3 and R-7 per inch, respectively. They are followed closely by polyurethane and polystyrene insulation at roughly R-6 and R-5 per inch. Loose cellulose, fiberglass (both blown and in batts), and rock wool (both blown and in batts) all possess an R-value of roughly R–2.5 to R–4 per inch. Straw bales perform at about R-1.5. However, typical straw bale houses have very thick walls and thus are well insulated. Snow is roughly R-1. The effective thermal resistance of an enclosed air cavity is strongly influenced by radiative heat transfer and distance between the two surfaces. All quality products at bargain prices. Occasionally, I list the same item with discounted prices for a limited time. Please Note: Due to the bulky size of this insulation, the 75 Square Meters are sent as follows. 1 Roll of 75 square meters – 1,500 mm wide 50 m long. 2 Rolls of 37.5 Square meters – 1,500 mm wide 25 m long each. 2 rolls of 37.5 Square meters each – 750 mm wide 50 m long. If you want your order in any specific combination, please let me know. Public holidays and weekends excluded. However, there is no guarantee that you will receive your parcel by the estimated date. The most economical method. If you wish to have your item delivered or handled in a special manner, let me know and I will inform you if there is any additional charge. If you live in a remote location with no courier service, let me know. Delays may be experienced in case of work overload, postal or courier. Delays, public holidays and weekends, or shortage of stock. If premises unattended, leave in a secure location. If premises unattended, place a card in the mailbox and leave parcel at nearest collection point. The parcel shall be deemed to have been delivered. If the parcel is sent by courier, a signature is usually required. You can select that the courier leaves the parcel. If it is not safe to leave the parcel by Your front door, then you will need to sign for it. All parcels will be securely packaged. For its loss or damage. Otherwords, all care taken and no responsibility accepted. No responsibility can be taken if you fail to provide a telephone number. Please note, I assume no responsibility if the item is delayed, lost or damaged n transit. No compensation will be paid until such investigation has been concluded. You will also need to arrange for your own packaging. International Buyers – Please Note. I strive to please my fellow eBayers. If you have any issue with the item, let me know. Errors & Omissions Excluded. No other warranties either expressed or implied are offered. You may find similar items cheaper with other sellers or retailers. I also rely on sighted assistants to help with the pictures and description. If you prefer to trade with a behemoth, please go elsewhere. From time to time I offer the same item cheaper for a limited period. The description of the items is as provided by the principal sellers and believed to be reliable. All feedback will be reciprocated. If you are happy with my service, tell the whole world, if you are not happy, tell me. If you have any issue with the item, contact me first before you post negative or neutral feedback. Issues can be resolved amicably. Leaving damaging feedback before your attempt to resolve any issue first will be deemed as defamatory and in contravention of the terms and conditions and will be dealt with accordingly. The bad Karma will result in proceedings for the removal of such feedback and will give rise of a liquidated claim for damages. Any unwarranted negative or neutral feedback will be removed using legal processes and may give rise to a liquidated claim for defamation or/ and breach of contract. All issues can be resolved amicably. An issue, contact me first. If you have any issues with your item, let me know and I will be happy to rectify any problem. If you post negative or neutral feedback without first letting me know of your intention to post such feedback will be deemed defamatory and may give rise to proceedings for defamation and/or breach of contract and will give rise to a liquidated claim for damages. If you have in issue, it would be quicker to contact me first and I will do my utmost to help you. If you do not wish to have feedback posted for you – for privacy reasons or otherwise – just let me know and I will not post feedback for you or simply do not post feedback for me. All brand names & trademarks are the property of their respective holders and are referred to here for descriptive purpose only. The listed brand names and model designations are intended only to show the compatibility of these products with various products. Pictures are for descriptive purposes only. All dimensions and measurements are approximate. Colour is as shown unless otherwise stated. Colour may vary depending on lighting, your computer screen resolution or angle of viewing. Please exercise care when you open your package when you receive it. Do not slash the packing material with a knife as to damage the contents of the package. Open carefully so you don’t drop the contents in case of fragile or breakable items. If the information is not correct, please provide your correct contact information. You agree to abide by the herein Terms & Conditions and any further amendments. Any dispute arising out of this. Agreement or the interpretation thereof. Shall be decided and. Settled in accordance with the laws and statues of the State of New South Wales, Australia. The parties agree that the venue shall be Sydney, New south Wales. This item is in the category “Home & Garden\Other Home & Garden”. The seller is “eddiesolomon777″ and is located in this country: AU. This item can be shipped worldwide.
  • Modified Item: No
  • Style: Double Sided Foil
  • Custom Bundle: No
  • Product Type: Silver Foil Bubble Wrap Insulation
  • Type: Roll
  • MPN: SFBI2
  • Room: ALL ROOMS
  • Brand: EDDIE SOLOMON
  • UPC: 722197213819

Thick Heavy Duty Double Foil Air Bubble Cell Insulation 75 Sqm Large Bubbles

SILVER AIR FOIL BUBBLE CELL INSULATION 25 SQM 50CM w AUSTRALIA MADE CSIRO TEST

Posted on by
SILVER_AIR_FOIL_BUBBLE_CELL_INSULATION_25_SQM_50CM_w_AUSTRALIA_MADE_CSIRO_TEST_01_acd SILVER AIR FOIL BUBBLE CELL INSULATION 25 SQM 50CM w AUSTRALIA MADE CSIRO TEST
SILVER AIR FOIL BUBBLE CELL INSULATION 25 SQM 50CM w AUSTRALIA MADE CSIRO TEST
SILVER AIR FOIL BUBBLE CELL INSULATION 25 SQM 50CM w AUSTRALIA MADE CSIRO TEST
SILVER AIR FOIL BUBBLE CELL INSULATION 25 SQM 50CM w AUSTRALIA MADE CSIRO TEST
SILVER AIR FOIL BUBBLE CELL INSULATION 25 SQM 50CM w AUSTRALIA MADE CSIRO TEST
SILVER AIR FOIL BUBBLE CELL INSULATION 25 SQM 50CM w AUSTRALIA MADE CSIRO TEST

SILVER AIR FOIL BUBBLE CELL INSULATION 25 SQM 50CM w AUSTRALIA MADE CSIRO TEST
Thank you for viewing my listing. SINGLE FOIL REFLECTIVE INSULATION. REDUCE RADIANT HEAT TRANSFER. IDEAL FOR HOT OR COLD CLIMATE. IDEAL FOR HOT AND COLD CLIMATE. ALSO AVAILABLE THE EXTRA HEAVY DUTY EXTRA THICK FOIL BUBBLE INSULATION. FIRE RESISTANT COMPLIES WITH AUSTRALIAN & NZ STANDARDS. SILVER FOIL BUBBLE INSULATION FOR EXTRA PROTECTION. 500 MM WIDE (20). 50 METRES LONG (165 FEET). 10 MM (3/8) DIAMETER BUBBLES. 4 MM THICK (3/16) BUBBLES. THE CHINESE AND IMPORTED INSULATION COMES IN ROLLS OF 1,200MM WIDE. THIS AUSTRALIAN MADE PRODUCT COMES IN ROLLS OF 1,500MM, 750MM. Call Eddie Solomon if you have any question. TO VIEW ALL FOIL BUBBLE INSULATION. SINGLE SILVER FOIL BUBBLE INSULATION. Single Foil Insulation is available in various size rolls. It consists of a layer of polyethylene bubbles and a layer of 99% pure aluminum radiant barrier foil. Double Foil Bubble Insulation is also available at extra cost. This style can be used in a variety of applications because it’s light weight and easy to handle yet provides superior protection. The bubble layer creates maximum R-Value and the reflective foil allows it to reflect 97% of radiant heat away from a structure on the outside and back in on a structure from the inside. This is why it works effectively in both hot and cold climates. Single Foil Reflective Insulation is a versatile insulation consisting of a 4.8 mil thick – 10 mm diameter -layer of polyethylene bubbles backed by a sheet of highly reflective, 99% aluminum. Reflective Bubble Insulation provides superior reflectivity of radiant heat while providing protection against conductive heat gain and loss as well as performing as a vapor barrier. Also available double Foil Insulation Bubble Wrap for ultimate protection and higher R value. Foil bubble insulation is ideal for metal building and commercial roof applications where the product will be seen and where aesthetics are important. The reflective surface can even make an area brighter, effectively cutting down on the electricity needed to meet lighting requirements. Foil bubble wrap can also be applied to windows to keep out the glare of the sun, and also to keep heat in or out depending on the weather. This is Foil lined Bubble Wrap on one side. ADVANTAGES OF THIS PRODUCT. Very effective in warmer climates. No change thermal performance over time due to compaction, disintegration or moisture absorption. Thin sheets takes up less room than bulk insulation. Can act as a vapor barrier. Will not mold or mildew. Radon retarder, will limit radon penetration through the floor. This is a high quality industrial strength Foil Silver Foil Insulation Bubble Wrap. Long lasting, heavy duty nylon barrier layer to increase longevity. Bubble Wrap is Lightweight and easy to use. It is an inexpensive solution to your insulation needs. This 25 Square meters Insulation Silver Foil Bubble Wrap usually comes in 500 mm wide rolls. However, it may come in other witths totalling 25 Square meters depending on availability. Our standard single and double bubble foil insulation is. Silver foil Available in a range of widths, from. 375 mm 15″ to 1,500 mm (60″), and lengths. We offer double-sided Silver. Aluminium products, as well as products covered with Silver Foil. On one side and white polyethylene on the other. This durable bubble insulation will withstand temperatures between -50 degrees Celsius. And 82 degrees Celsius (180 degrees Fahrenheit), making it ideal for both attic and flooring installations. Be sure to check out our silver Foil Aluminium. This is the best tape for bubble foil insulation because it ensures the continuity of the reflective surface, which is essential for getting the most from your installation. Radiant floor heating has been in use for centuries and radiant barriers help to retain the heat generated by the radiant heating system blocking it from escaping into the ground. Silver foil bubble Wrap. Insulation is extremely tough and pliable, easy to install, and is an excellent vapor barrier for all your radiant floor heating applications, thus greatly reducing your electricity or gas bills. Silver Foil Bubble wrap. Insulation installed in crawl spaces below a building structure reflect the heat flows that are flowing downward from the flooring back up into the flooring at a 95-97% rate providing increased comfort and heat retention. The temperature of the cold floors which cause cold feet will be raised while your heating bill is reduced, providing for increased comfort. As heat is reflected back into the living area, it warms other objects which then radiate heat back into the room, further increasing your living comfort. Metal & Steel Buildings. Temperature sensitive storage areas. Silver foil Bubble Wrap. Insulation applications are only limited by your imagination. The main feature of this insulation is its reflective nature and not the thickness of the material. It has a nominal thickness of 4.8 mm and easy to handle. We can also custom make any combination to suit your requirements. You can have foam sandwiched between two layers of Silver foil, Or thicker bubbles between tow layers of foil, or any combination you require. Please note custom made insulation attracts minimum order of 1,500 Square meters. Custom orders are final. All the insulation is made right here in Australia with the highest standard of material and manufacture. All quality products at bargain prices. CSIRO- Materials Science & Engineering. (ABN: 41 687 119 230). Page 1 of 1. Sample Description: silver insulation material designed for pallet protection. At an ambient temperature of 23.1ºC – difference from face to back 2.4ºC. At an ambient temperature of 28.6ºC – difference from face to back 5.1ºC. OF THE INSULATIVE EFFECTIVENESS OF SINGLE-SIDED 10 MILLIMETRE BUBBLE FILM (4.8 mm Thick). LAMINATED WITH METALLISED P. THE TRUTH ABOUT R VALUE. Around most of the world, R-values are given in SI units, typically square-metre kelvin per watt or m2·K/W (or equally, m2·°C/W). In the United States customary units, R-values are given in units of ft2·°F·hr/Btu. It is particularly easy to confuse SI and US R-values, because R-values both in the US and elsewhere are often cited without their units, e. Usually, however, the correct units can be inferred from the context and from the magnitudes of the values. United States R-values are approximately six times SI R-values. The conversion between SI and US units of R-value is 1 h·ft2·°F/Btu = 0.176110 K·m2/W, or 1 K·m2/W = 5.678263 h·ft2·°F/Btu. As an example an R11 in the United States is approximately R2 in SI units in Europe, Australia and the rest of the world. An R value advertised by a United States merchant may appear more appealing as the US R value is 6 times higher than SI values used in the rest of the world. It does not mean that a US R value is more effective than An R value used in Europe, Australia or the rest of the world. Do not rely on the R value provided by the supplier as the R value may increase or decrease depending on the application. Furthermore, the actual R value of the insulation depends entirely on the application and how you apply the insulation. An R 2 value may increase or decrease depending on how the insulation is applied. With the Silver Foil bubble Insulation you will need an air pocket between the surface. Of the structure you are insulating. And the insulation material. The air pocket has its own r value depending on the width of the air pocket thus increasing the R value of the insulation material. Conversely, if you apply the insulation material directly on the surface of the structure will defeat the purpose of insulation because the insulation material will act as a heat conductor and will end up heating the premises in the hot summer and will also be counterproductive in winter. Radiation is minimized by low emissivity (highly reflective) exterior surfaces such as aluminum foil. Lower thermal conductivity, or higher R-values, can be achieved by allowing an air gap between the surface of the structure and the aluminium foil. The air gap will act an heat pocket where heat will accumulate instead of being circulation inside your structure. Trapped air has its own R value. The R value of trapped air depends on how much gap is between the insulation material an the structure. A wider gap will produce a greater R value and a narrower. Gap will produce a smaller R value. Air by itself has no R value; only trapped air will produce an R value. However, if you allow a very wide gap, the air will not be trapped and may reduce your R value and cause an opposite result. The R-value is a measure of an insulation sample’s ability to reduce the rate of heat flow under specified test conditions. The primary mode of heat transfer impeded by insulation is conduction, but insulation also reduces heat loss by all three heat transfer modes: conduction, convection, and radiation. The primary means of heat loss across an uninsulated air-filled space is natural convection, which occurs because of changes in air density with temperature. Insulation greatly retards natural convection making the primary mode of heat transfer conduction. To find the heat loss per square meter, simply divide the temperature difference by the R value. If the interior of a home is at 20 °C, and the roof cavity is at 10 °C, the temperature difference is 10 C° (= 10 K difference). Assuming a ceiling insulated to R-2 (R = 2.0 m2K/W), energy will be lost at a rate of 10 K/2 K·m2/W = 5 watts for every square meter of ceiling. Doubling the thickness of the insulation material or even doubling the thickness of the trapped air layer doubles the R value. This does not hold for compressed bats of glass wool because compressing the bats does not proportionally increase the r value. Furthermore, doubling the thickness of the Silver Foil Bubble Insulation does not double the R value of the insulation material. The main feature of the Silver Backed Bubble Insulation is its reflective nature and not its thickness. To Double the R value of the Foil Bubble Insulation you will need to create a heat pocket which hads it s own R value that can be added to the R value of the Foil Insulation. As an example, the if Foil Bubble Insulation has an R value of r2 and the. Heat pocket has an R value of R 1,5, both R value are added together to achieve an R value of R3.5 in SI units or R19 in United States standards. As discussed earlier porous material such as foam and bats does not allow the full potential of trapped air to be established and will not give you the proportional R value relative to thickness. In calculating the R-value of a multi-layered installation, the R-values of the individual layers are added:[10]. R-value(outside air film) + R-value(brick) + R-value(sheathing) + R-value(insulation) + R-value(plasterboard) + R-value(inside air film) = R-value(total). To account for other components in a wall such as framing, an area-weighted average R-value of the whole wall may be calculated. For the most part, testing the R-value of insulation is done at a steady temperature, usually about 70 °F (21 °C) with no surrounding air movement. Since these are ideal conditions, the listed R-value for insulation will almost certainly be higher than it would be in actual use, because most situations with insulation are under different conditions. Some types of foam insulation, such as polyurethane and polyisocyanurate are blown with heavy gases such as chlorofluorocarbons (CFC) or hydrochlorofluorocarbons (HFCs). However, over time a small amount of these gases diffuse out of the foam and are replaced by air, thus reducing the effective R-value of the product. This has led to controversy as how to rate the insulation of these products. Many manufacturers will rate the R-value at the time of manufacture; critics argue that a more fair assessment would be its settled value. [citation needed] The foam industrywhen? Adopted the LTTR (Long-Term Thermal Resistance) method, [14] which rates the R-value based on a 15 year weighted average. However, the LTTR effectively provides only an eight-year aged R-value, short in the scale of a building that may have a lifespan of 50 to 100 years. Note that these examples use the non-SI definition and/or given for a 1 inch (25.4 mm) thick sample. Vacuum insulated panels have the highest R-value (approximately R-45 per inch in American customary units); aerogel has the next highest R-value (about R-10-30 per inch), followed by isocyanurate and phenolic foam insulations with, R-8.3 and R-7 per inch, respectively. They are followed closely by polyurethane and polystyrene insulation at roughly R-6 and R-5 per inch. Loose cellulose, fiberglass (both blown and in batts), and rock wool (both blown and in batts) all possess an R-value of roughly R–2.5 to R–4 per inch. Straw bales perform at about R-1.5. However, typical straw bale houses have very thick walls and thus are well insulated. Snow is roughly R-1. The effective thermal resistance of an enclosed air cavity is strongly influenced by radiative heat transfer and distance between the two surfaces. Occasionally, I list the same item with discounted prices for a limited time. To check my other items go to. Public holidays and weekends excluded. However, there is no guarantee that you will receive your parcel by the estimated date. The most economical method. If you wish to have your item delivered or handled in a special manner, let me know and I will inform you if there is any additional charge. If you live in a remote location with no courier service, let me know. Delays may be experienced in case of work overload, postal or courier. Delays, public holidays and weekends, or shortage of stock. If premises unattended, leave in a secure location. If premises unattended, place a card in the mailbox and leave parcel at nearest collection point. The parcel shall be deemed to have been delivered. If the parcel is sent by courier, a signature is usually required. You can select that the courier leaves the parcel. If it is not safe to leave the parcel by Your front door, then you will need to sign for it. All parcels will be securely packaged. For its loss or damage. Otherwords, all care taken and no responsibility accepted. No responsibility can be taken if you fail to provide a telephone number. Please note, I assume no responsibility if the item is delayed, lost or damaged n transit. No compensation will be paid until such investigation has been concluded. You will also need to arrange for your own packaging. International Buyers – Please Note. I strive to please my fellow eBayers. If you have any issue with the item, let me know. Errors & Omissions Excluded. No other warranties either expressed or implied are offered. You may find similar items cheaper with other sellers or retailers. I also rely on sighted assistants to help with the pictures and description. If you prefer to trade with a behemoth, please go elsewhere. From time to time I offer the same item cheaper for a limited period. The description of the items is as provided by the principal sellers and believed to be reliable. All feedback will be reciprocated. If you are happy with my service, tell the whole world, if you are not happy, tell me. If you have any issue with the item, contact me first before you post negative or neutral feedback. Issues can be resolved amicably. Leaving damaging feedback before your attempt to resolve any issue first will be deemed as defamatory and in contravention of the terms and conditions and will be dealt with accordingly. The bad Karma will result in proceedings for the removal of such feedback and will give rise of a liquidated claim for damages. Any unwarranted negative or neutral feedback will be removed using legal processes and may give rise to a liquidated claim for defamation or/ and breach of contract. All issues can be resolved amicably. An issue, contact me first. If you have any issues with your item, let me know and I will be happy to rectify any problem. If you post negative or neutral feedback without first letting me know of your intention to post such feedback will be deemed defamatory and may give rise to proceedings for defamation and/or breach of contract and will give rise to a liquidated claim for damages. If you have in issue, it would be quicker to contact me first and I will do my utmost to help you. If you do not wish to have feedback posted for you – for privacy reasons or otherwise – just let me know and I will not post feedback for you or simply do not post feedback for me. All brand names & trademarks are the property of their respective holders and are referred to here for descriptive purpose only. The listed brand names and model designations are intended only to show the compatibility of these products with various products. Pictures are for descriptive purposes only. All dimensions and measurements are approximate. Colour is as shown unless otherwise stated. Colour may vary depending on lighting, your computer screen resolution or angle of viewing. Please exercise care when you open your package when you receive it. Do not slash the packing material with a knife as to damage the contents of the package. Open carefully so you don’t drop the contents in case of fragile or breakable items. If the information is not correct, please provide your correct contact information. You agree to abide by the herein Terms & Conditions and any further amendments. Any dispute arising out of this. Agreement or the interpretation thereof. Shall be decided and. Settled in accordance with the laws and statues of the State of New South Wales, Australia. The parties agree that the venue shall be Sydney, New south Wales. This item is in the category “Industrial\Building Materials\Insulation & Accessories\Insulation”. The seller is “eddiesolomon777″ and is located in this country: AU. This item can be shipped worldwide.
  • Custom Bundle: No
  • Material: Foil backed bubble wrap
  • Type: Foil Bubble Insulation
  • Features: Heat Retardant
  • Insulation R-Value: R2
  • MPN: SFBI1
  • Product Type: Insulation
  • Model: ROLL
  • Modified Item: No
  • Packaging: Roll
  • Brand: EDDIE SOLOMON PACKAGING
  • Suitable For: Caravan, Campervan, Car, Truck, Boat, Dog House, Water Bottle, Keep Food Fresh, Window Shades, Attic/Loft, Basement, Ceiling, Floor, Garage, Interior Wall
  • UPC: 0602401607958

SILVER AIR FOIL BUBBLE CELL INSULATION 25 SQM 50CM w AUSTRALIA MADE CSIRO TEST

Heavy Duty Thick Double Foil Air Bubbl Cell Insulation 40 Sq M. Free Shipping

Posted on by
Heavy_Duty_Thick_Double_Foil_Air_Bubbl_Cell_Insulation_40_Sq_M_Free_Shipping_01_aety Heavy Duty Thick Double Foil Air Bubbl Cell Insulation 40 Sq M. Free Shipping
Heavy Duty Thick Double Foil Air Bubbl Cell Insulation 40 Sq M. Free Shipping
Heavy Duty Thick Double Foil Air Bubbl Cell Insulation 40 Sq M. Free Shipping
Heavy Duty Thick Double Foil Air Bubbl Cell Insulation 40 Sq M. Free Shipping
Heavy Duty Thick Double Foil Air Bubbl Cell Insulation 40 Sq M. Free Shipping
Heavy Duty Thick Double Foil Air Bubbl Cell Insulation 40 Sq M. Free Shipping
Heavy Duty Thick Double Foil Air Bubbl Cell Insulation 40 Sq M. Free Shipping

Heavy Duty Thick Double Foil Air Bubbl Cell Insulation 40 Sq M. Free Shipping
Thank you for viewing my listing. DOUBLE SIDED SILVER FOIL. NOMINAL 8 MM THICK BUBBLES. TWO LAYERS OF FOIL. REDUCE RADIANT HEAT TRANSFER. IDEAL FOR HOT OR COLD CLIMATE. PLEASE NOTE: THIS INSULATION CONSIST OF A LAYER OF AIR BUBBLES 20MM DIAMETR 8MM THICK SANDWICHED BETWEEN 2 LAYERS OF ALUMINIUM REFLECTIVE FOIL. DUE TO COMPRESSION THE 8MM THICKNESS MAY BE REDUCED SLIGHTLY. IF YOU WANT AN EXACT 8MM THICKNESS, THIS MAY NOT SUIT YOU. ALSO AVAILABLE THE FIRE RETARDANT FOIL INSULATION. 40 SQUARE METERS (440 SQUARE FEET). 26.7 METER LONG X 1.5 METER WIDE. 20 MM (3/4) DIAMETER BUBBLES. 8 MM THICK (3/8) BUBBLES BEFORE COMPRESSION BY FOIL. TWO LAYERS OF ALUMINUM FOIL. Call Eddie Solomon if you have any question. Please Note: this product does not comply with Australian Standards nor the Building Code but it is tested by Australian CSIRO and has been used widely for home insulation. TO VIEW ALL FOIL BUBBLE INSULATION. SILVER FOIL BUBBLE INSULATION. Double Foil Insulation is available in 75 Square Meters rolls – 1,500 mm wide x 50 Meters long. It consists of a layer of polyethylene bubbles that is sandwiched between two layers of 99% pure aluminum radiant barrier foil. This style can be used in a variety of applications because it’s light weight and easy to handle yet provides superior protection. The bubble center creates maximum R-Value and the reflective foil on both sides allow it to reflect 97% of radiant heat away from a structure on the outside and back in on a structure from the inside. This is why it works effectively in both hot and cold climates. Double Foil Reflective Insulation is a versatile insulation consisting of an 4.8 mm thick – 10 mm diameter layer of polyethylene bubbles sandwiched between two sheets of highly reflective, 99% aluminum. Reflective Bubble Insulation provides superior reflectivity of radiant heat while providing protection against conductive heat gain and loss as well as performing as a vapor barrier. Nominal Thickness 1/4 – 0.6 mm. Weight 0.5 oz / sq. Ft – 160 g/sq m. Temperature Range – ASTM C411 -50 F to 180 F (-45 c to 82 c). Flame Spread (ASTM E84-05) 5. Smoke Development (ASTM E84-05) 5. Emissivity – ASTM C1371 0.03-0.04. Reflectivity – ASTM 3903 0.96-0.97. Water Vapor Permeance-ASTM E96. Flexibility – No Cracking. Resistant to Fungi and Bacteria Does not promote growth. ADVANTAGES OF THIS PRODUCT. Very effective in warmer climates. No change to thermal performance over time due to compaction, disintegration or moisture absorption. Thin sheets takes up less room than bulk insulation. Can act as a vapor barrier. Will not mold or mildew. Radon retarder, will limit radon penetration through the floor. This is a high quality industrial strength Double Foil Insulation Bubble Wrap. Long lasting, heavy duty nylon barrier layer to increase longevity. Bubble Wrap is Lightweight and easy to use. It is an inexpensive solution to your insulation needs. This 75 Square meter Silver Insulation Foil Bubble Wrap usually comes in rolls of 1,500 mm wide. However, it may come in other widths totalling 75 Square meter depending on availability. Our standard single and double bubble foil insulation is. Silver foil Available in a range of widths, from. 375 mm 15″ to 1,500 mm (60″), and lengths. We offer double-sided Silver. Aluminium products, as well as products covered with Silver Foil. On one side and white polyethylene on the other. This durable bubble insulation will withstand temperatures between -50 degrees Celsius. And 82 degrees Celsius (180 degrees Fahrenheit), making it ideal for both attic and flooring installations. Be sure to check out our silver Foil Aluminium. This is the best tape for bubble foil insulation because it ensures the continuity of the reflective surface, which is essential for getting the most from your installation. Radiant floor heating has been in use for centuries and radiant barriers help to retain the heat generated by the radiant heating system blocking it from escaping into the ground. Silver foil bubble Wrap. Insulation is extremely tough and pliable, easy to install, and is an excellent vapor barrier for all your radiant floor heating applications, thus greatly reducing your electricity or gas bills. Silver Foil Bubble wrap. Insulation installed in crawl spaces below a building structure reflect the heat flows that are flowing downward from the flooring back up into the flooring at a 95-97% rate providing increased comfort and heat retention. The temperature of the cold floors which cause cold feet will be raised while your heating bill is reduced, providing for increased comfort. As heat is reflected back into the living area, it warms other objects which then radiate heat back into the room, further increasing your living comfort. Metal & Steel Buildings. Temperature sensitive storage areas. Silver foil Bubble Wrap. Insulation applications are only limited by your imagination. The main feature of this insulation is its reflective nature and not the thickness of the material. It has a nominal thickness of 4.8 mm and easy to handle. We can also custom make any combination to suit your requirements. You can have foam sandwiched between two layers of Silver foil, Or thicker bubbles between tow layers of foil, or any combination you require. Please note custom made insulation attracts minimum order of 1,500 Square meters. Custom orders are final. All the insulation is made right here in Australia with the highest standard of material and manufacture. The following Test Report conducted by the Australian CSIRO on the single Foil Bubble Insulation. This listing is for the Double Foil Bubble Insulation which commands a higher insulation quality tham the single. CSIRO- Materials Science & Engineering. (ABN: 41 687 119 230). Page 1 of 1. Sample Description: silver insulation material designed for pallet protection. At an ambient temperature of 23.1ºC – difference from face to back 2.4ºC. At an ambient temperature of 28.6ºC – difference from face to back 5.1ºC. OF THE INSULATIVE EFFECTIVENESS OF SINGLE-SIDED 10 MILLIMETRE BUBBLE FILM (4.8 mm Thick). LAMINATED WITH METALLISED P. THE TRUTH ABOUT R VALUE. Around most of the world, R-values are given in SI units, typically square-metre kelvin per watt or m2·K/W (or equally, m2·°C/W). In the United States customary units, R-values are given in units of ft2·°F·hr/Btu. It is particularly easy to confuse SI and US R-values, because R-values both in the US and elsewhere are often cited without their units, e. Usually, however, the correct units can be inferred from the context and from the magnitudes of the values. United States R-values are approximately six times SI R-values. The conversion between SI and US units of R-value is 1 h·ft2·°F/Btu = 0.176110 K·m2/W, or 1 K·m2/W = 5.678263 h·ft2·°F/Btu. As an example an R11 in the United States is approximately R2 in SI units in Europe, Australia and the rest of the world. An R value advertised by a United States merchant may appear more appealing as the US R value is 6 times higher than SI values used in the rest of the world. It does not mean that a US R value is more effective than An R value used in Europe, Australia or the rest of the world. Do not rely on the R value provided by the supplier as the R value may increase or decrease depending on the application. Furthermore, the actual R value of the insulation depends entirely on the application and how you apply the insulation. An R 2 value may increase or decrease depending on how the insulation is applied. With the Silver Foil bubble Insulation you will need an air pocket between the surface. Of the structure you are insulating. And the insulation material. The air pocket has its own r value depending on the width of the air pocket thus increasing the R value of the insulation material. Conversely, if you apply the insulation material directly on the surface of the structure will defeat the purpose of insulation because the insulation material will act as a heat conductor and will end up heating the premises in the hot summer and will also be counterproductive in winter. Radiation is minimized by low emissivity (highly reflective) exterior surfaces such as aluminum foil. Lower thermal conductivity, or higher R-values, can be achieved by allowing an air gap between the surface of the structure and the aluminium foil. The air gap will act an heat pocket where heat will accumulate instead of being circulation inside your structure. Trapped air has its own R value. The R value of trapped air depends on how much gap is between the insulation material an the structure. A wider gap will produce a greater R value and a narrower. Gap will produce a smaller R value. Air by itself has no R value; only trapped air will produce an R value. However, if you allow a very wide gap, the air will not be trapped and may reduce your R value and cause an opposite result. The R-value is a measure of an insulation sample’s ability to reduce the rate of heat flow under specified test conditions. The primary mode of heat transfer impeded by insulation is conduction, but insulation also reduces heat loss by all three heat transfer modes: conduction, convection, and radiation. The primary means of heat loss across an uninsulated air-filled space is natural convection, which occurs because of changes in air density with temperature. Insulation greatly retards natural convection making the primary mode of heat transfer conduction. To find the heat loss per square meter, simply divide the temperature difference by the R value. If the interior of a home is at 20 °C, and the roof cavity is at 10 °C, the temperature difference is 10 C° (= 10 K difference). Assuming a ceiling insulated to R-2 (R = 2.0 m2K/W), energy will be lost at a rate of 10 K/2 K·m2/W = 5 watts for every square meter of ceiling. Doubling the thickness of the insulation material or even doubling the thickness of the trapped air layer doubles the R value. This does not hold for compressed bats of glass wool because compressing the bats does not proportionally increase the r value. Furthermore, doubling the thickness of the Silver Foil Bubble Insulation does not double the R value of the insulation material. The main feature of the Silver Backed Bubble Insulation is its reflective nature and not its thickness. To Double the R value of the Foil Bubble Insulation you will need to create a heat pocket which hads it s own R value that can be added to the R value of the Foil Insulation. As an example, the if Foil Bubble Insulation has an R value of r2 and the. Heat pocket has an R value of R 1,5, both R value are added together to achieve an R value of R3.5 in SI units or R19 in United States standards. As discussed earlier porous material such as foam and bats does not allow the full potential of trapped air to be established and will not give you the proportional R value relative to thickness. In calculating the R-value of a multi-layered installation, the R-values of the individual layers are added:[10]. R-value(outside air film) + R-value(brick) + R-value(sheathing) + R-value(insulation) + R-value(plasterboard) + R-value(inside air film) = R-value(total). To account for other components in a wall such as framing, an area-weighted average R-value of the whole wall may be calculated. For the most part, testing the R-value of insulation is done at a steady temperature, usually about 70 °F (21 °C) with no surrounding air movement. Since these are ideal conditions, the listed R-value for insulation will almost certainly be higher than it would be in actual use, because most situations with insulation are under different conditions. Some types of foam insulation, such as polyurethane and polyisocyanurate are blown with heavy gases such as chlorofluorocarbons (CFC) or hydrochlorofluorocarbons (HFCs). However, over time a small amount of these gases diffuse out of the foam and are replaced by air, thus reducing the effective R-value of the product. This has led to controversy as how to rate the insulation of these products. Many manufacturers will rate the R-value at the time of manufacture; critics argue that a more fair assessment would be its settled value. [citation needed] The foam industrywhen? Adopted the LTTR (Long-Term Thermal Resistance) method, [14] which rates the R-value based on a 15 year weighted average. However, the LTTR effectively provides only an eight-year aged R-value, short in the scale of a building that may have a lifespan of 50 to 100 years. Note that these examples use the non-SI definition and/or given for a 1 inch (25.4 mm) thick sample. Vacuum insulated panels have the highest R-value (approximately R-45 per inch in American customary units); aerogel has the next highest R-value (about R-10-30 per inch), followed by isocyanurate and phenolic foam insulations with, R-8.3 and R-7 per inch, respectively. They are followed closely by polyurethane and polystyrene insulation at roughly R-6 and R-5 per inch. Loose cellulose, fiberglass (both blown and in batts), and rock wool (both blown and in batts) all possess an R-value of roughly R–2.5 to R–4 per inch. Straw bales perform at about R-1.5. However, typical straw bale houses have very thick walls and thus are well insulated. Snow is roughly R-1. The effective thermal resistance of an enclosed air cavity is strongly influenced by radiative heat transfer and distance between the two surfaces. All quality products at bargain prices. Occasionally, I list the same item with discounted prices for a limited time. Please Note: Due to the bulky size of this insulation, the 75 Square Meters are sent as follows. 1 Roll of 75 square meters – 1,500 mm wide 50 m long. 2 Rolls of 37.5 Square meters – 1,500 mm wide 25 m long each. 2 rolls of 37.5 Square meters each – 750 mm wide 50 m long. Public holidays and weekends excluded. However, there is no guarantee that you will receive your parcel by the estimated date. The most economical method. If you wish to have your item delivered or handled in a special manner, let me know and I will inform you if there is any additional charge. If you live in a remote location with no courier service, let me know. Delays may be experienced in case of work overload, postal or courier. Delays, public holidays and weekends, or shortage of stock. If premises unattended, leave in a secure location. If premises unattended, place a card in the mailbox and leave parcel at nearest collection point. The parcel shall be deemed to have been delivered. If the parcel is sent by courier, a signature is usually required. You can select that the courier leaves the parcel. If it is not safe to leave the parcel by Your front door, then you will need to sign for it. All parcels will be securely packaged. For its loss or damage. Otherwords, all care taken and no responsibility accepted. No responsibility can be taken if you fail to provide a telephone number. Please note, I assume no responsibility if the item is delayed, lost or damaged n transit. No compensation will be paid until such investigation has been concluded. You will also need to arrange for your own packaging. International Buyers – Please Note. I strive to please my fellow eBayers. If you have any issue with the item, let me know. Errors & Omissions Excluded. No other warranties either expressed or implied are offered. You may find similar items cheaper with other sellers or retailers. I also rely on sighted assistants to help with the pictures and description. If you prefer to trade with a behemoth, please go elsewhere. From time to time I offer the same item cheaper for a limited period. The description of the items is as provided by the principal sellers and believed to be reliable. All feedback will be reciprocated. If you are happy with my service, tell the whole world, if you are not happy, tell me. If you have any issue with the item, contact me first before you post negative or neutral feedback. Issues can be resolved amicably. Leaving damaging feedback before your attempt to resolve any issue first will be deemed as defamatory and in contravention of the terms and conditions and will be dealt with accordingly. The bad Karma will result in proceedings for the removal of such feedback and will give rise of a liquidated claim for damages. Any unwarranted negative or neutral feedback will be removed using legal processes and may give rise to a liquidated claim for defamation or/ and breach of contract. All issues can be resolved amicably. An issue, contact me first. If you have any issues with your item, let me know and I will be happy to rectify any problem. If you post negative or neutral feedback without first letting me know of your intention to post such feedback will be deemed defamatory and may give rise to proceedings for defamation and/or breach of contract and will give rise to a liquidated claim for damages. If you have in issue, it would be quicker to contact me first and I will do my utmost to help you. If you do not wish to have feedback posted for you – for privacy reasons or otherwise – just let me know and I will not post feedback for you or simply do not post feedback for me. All brand names & trademarks are the property of their respective holders and are referred to here for descriptive purpose only. The listed brand names and model designations are intended only to show the compatibility of these products with various products. Pictures are for descriptive purposes only. All dimensions and measurements are approximate. Colour is as shown unless otherwise stated. Colour may vary depending on lighting, your computer screen resolution or angle of viewing. Please exercise care when you open your package when you receive it. Do not slash the packing material with a knife as to damage the contents of the package. Open carefully so you don’t drop the contents in case of fragile or breakable items. If the information is not correct, please provide your correct contact information. You agree to abide by the herein Terms & Conditions and any further amendments. Any dispute arising out of this. Agreement or the interpretation thereof. Shall be decided and. Settled in accordance with the laws and statues of the State of New South Wales, Australia. The parties agree that the venue shall be Sydney, New south Wales. This item is in the category “Home & Garden\Other Home & Garden”. The seller is “eddiesolomon777″ and is located in this country: AU. This item can be shipped worldwide.
  • Modified Item: No
  • Style: Double Sided Foil
  • Custom Bundle: No
  • Product Type: Silver Foil Bubble Wrap Insulation
  • Type: Roll
  • MPN: SFBI2
  • Brand: EDDIE SOLOMON
  • UPC: 722197213819

Heavy Duty Thick Double Foil Air Bubbl Cell Insulation 40 Sq M. Free Shipping

Heavy Duty Double Foil Air Bubble Silver Cell Insulation 75 Sq M Free Shipping

Posted on by
Heavy_Duty_Double_Foil_Air_Bubble_Silver_Cell_Insulation_75_Sq_M_Free_Shipping_01_vzga Heavy Duty Double Foil Air Bubble Silver Cell Insulation 75 Sq M Free Shipping
Heavy Duty Double Foil Air Bubble Silver Cell Insulation 75 Sq M Free Shipping
Heavy Duty Double Foil Air Bubble Silver Cell Insulation 75 Sq M Free Shipping
Heavy Duty Double Foil Air Bubble Silver Cell Insulation 75 Sq M Free Shipping
Heavy Duty Double Foil Air Bubble Silver Cell Insulation 75 Sq M Free Shipping
Heavy Duty Double Foil Air Bubble Silver Cell Insulation 75 Sq M Free Shipping

Heavy Duty Double Foil Air Bubble Silver Cell Insulation 75 Sq M Free Shipping
DOUBLE SIDED SILVER FOIL. TWO LAYERS OF FOIL. REDUCE RADIANT HEAT TRANSFER. IDEAL FOR HOT OR COLD CLIMATE. ALSO AVAILABLE THE EXTRA HEAVY DUTY THICKER SILVER FOIL BUBBLE INSULATION WITH HIGHER R VALUE FOR EXTRA PROTECTION. 1500 MM WIDE (60). 50 METRES LONG (165 FEET). 750 MM WIDE (30). 100 METERS LONG (330 FEET). 75 SQUARE METERS (825 SQUARE FEET). 10 MM (3/8) DIAMETER BUBBLES. 4 MM THICK (3/16) BUBBLES. TWO LAYERS OF ALUMINUM FOIL. Call Eddie Solomon if you have any question. IT COMES WITH AUSTRALIAN CSIRO TEST REPORT. PLEASE NOTE: THIS PRODUCT DOE NOT COME WITH A COMPLIANCE CERTIFICATEFOR BUILDING INSPECTION PURPOSES. SILVER FOIL BUBBLE INSULATION. Double Foil Insulation is available in 75 Square Meters rolls – 1,500 mm wide x 50 Meters long. It consists of a layer of polyethylene bubbles that is sandwiched between two layers of 99% pure aluminum radiant barrier foil. This style can be used in a variety of applications because it’s light weight and easy to handle yet provides superior protection. The bubble center creates maximum R-Value and the reflective foil on both sides allow it to reflect 97% of radiant heat away from a structure on the outside and back in on a structure from the inside. This is why it works effectively in both hot and cold climates. Double Foil Reflective Insulation is a versatile insulation consisting of an 4.8 mm thick – 10 mm diameter layer of polyethylene bubbles sandwiched between two sheets of highly reflective, 99% aluminum. Reflective Bubble Insulation provides superior reflectivity of radiant heat while providing protection against conductive heat gain and loss as well as performing as a vapor barrier. Also available the Extra Heavy Duty Extra Thick Double Foil Bubble Insulation 13mm thick. Wholesale prices available for orders of 450 Square meters for the Single Foil, Double Foil and the Extra Heavy Duty Silver Foil Bubble Insulation. Also available silver Foil Insulation reinforced tape. Nominal Thickness 1/4 – 0.6 mm. Weight 0.5 oz / sq. Ft – 160 g/sq m. Temperature Range – ASTM C411 -50 F to 180 F (-45 c to 82 c). Flame Spread (ASTM E84-05) 5. Smoke Development (ASTM E84-05) 5. Emissivity – ASTM C1371 0.03-0.04. Reflectivity – ASTM 3903 0.96-0.97. Water Vapor Permeance-ASTM E96. Flexibility – No Cracking. Resistant to Fungi and Bacteria Does not promote growth. R3.5 value depending on application. ADVANTAGES OF THIS PRODUCT. Very effective in warmer climates. No change to thermal performance over time due to compaction, disintegration or moisture absorption. Thin sheets takes up less room than bulk insulation. Can act as a vapor barrier. Will not mold or mildew. Radon retarder, will limit radon penetration through the floor. This is a high quality industrial strength Double Foil Insulation Bubble Wrap. Long lasting, heavy duty nylon barrier layer to increase longevity. Bubble Wrap is Lightweight and easy to use. It is an inexpensive solution to your insulation needs. Our standard single and double bubble foil insulation is. Silver foil Available in a range of widths, from. 375 mm 15″ to 1,500 mm (60″), and lengths. We offer double-sided Silver. Aluminium products, as well as products covered with Silver Foil. On one side and white polyethylene on the other. This durable bubble insulation will withstand temperatures between -50 degrees Celsius. And 82 degrees Celsius (180 degrees Fahrenheit), making it ideal for both attic and flooring installations. Be sure to check out our silver Foil Aluminium. This is the best tape for bubble foil insulation because it ensures the continuity of the reflective surface, which is essential for getting the most from your installation. Radiant floor heating has been in use for centuries and radiant barriers help to retain the heat generated by the radiant heating system blocking it from escaping into the ground. Silver foil bubble Wrap. Insulation is extremely tough and pliable, easy to install, and is an excellent vapor barrier for all your radiant floor heating applications, thus greatly reducing your electricity or gas bills. Silver Foil Bubble wrap. Insulation installed in crawl spaces below a building structure reflect the heat flows that are flowing downward from the flooring back up into the flooring at a 95-97% rate providing increased comfort and heat retention. The temperature of the cold floors which cause cold feet will be raised while your heating bill is reduced, providing for increased comfort. As heat is reflected back into the living area, it warms other objects which then radiate heat back into the room, further increasing your living comfort. Metal & Steel Buildings. Temperature sensitive storage areas. Silver foil Bubble Wrap. Insulation applications are only limited by your imagination. The main feature of this insulation is its reflective nature and not the thickness of the material. It has a nominal thickness of 4.8 mm and easy to handle. We can also custom make any combination to suit your requirements. You can have foam sandwiched between two layers of Silver foil, Or thicker bubbles between tow layers of foil, or any combination you require. Please note custom made insulation attracts minimum order of 1,500 Square meters. Custom orders are final. All the insulation is made right here in Australia with the highest standard of material and manufacture. All quality products at bargain prices. Occasionally, I list the same item with discounted prices for a limited time. CSIRO- Materials Science & Engineering. (ABN: 41 687 119 230). Henry St, Belmont, Victoria 3216, Australia. Web: Arial Black>. Page 1 of 1. Sample Description: silver insulation material designed for pallet protection. At an ambient temperature of 23.1ºC – difference from face to back 2.4ºC. At an ambient temperature of 28.6ºC – difference from face to back 5.1ºC. OF THE INSULATIVE EFFECTIVENESS OF SINGLE-SIDED 10 MILLIMETRE BUBBLE FILM (4.8 mm Thick). LAMINATED WITH METALLISED P. THE TRUTH ABOUT R VALUE. Around most of the world, R-values are given in SI units, typically square-metre kelvin per watt or m2·K/W (or equally, m2·°C/W). In the United States customary units, R-values are given in units of ft2·°F·hr/Btu. It is particularly easy to confuse SI and US R-values, because R-values both in the US and elsewhere are often cited without their units, e. Usually, however, the correct units can be inferred from the context and from the magnitudes of the values. United States R-values are approximately six times SI R-values. The conversion between SI and US units of R-value is 1 h·ft2·°F/Btu = 0.176110 K·m2/W, or 1 K·m2/W = 5.678263 h·ft2·°F/Btu. As an example an R11 in the United States is approximately R2 in SI units in Europe, Australia and the rest of the world. An R value advertised by a United States merchant may appear more appealing as the US R value is 6 times higher than SI values used in the rest of the world. It does not mean that a US R value is more effective than An R value used in Europe, Australia or the rest of the world. Do not rely on the R value provided by the supplier as the R value may increase or decrease depending on the application. Furthermore, the actual R value of the insulation depends entirely on the application and how you apply the insulation. An R 2 value may increase or decrease depending on how the insulation is applied. With the Silver Foil bubble Insulation you will need an air pocket between the surface. Of the structure you are insulating. And the insulation material. The air pocket has its own r value depending on the width of the air pocket thus increasing the R value of the insulation material. Conversely, if you apply the insulation material directly on the surface of the structure will defeat the purpose of insulation because the insulation material will act as a heat conductor and will end up heating the premises in the hot summer and will also be counterproductive in winter. Radiation is minimized by low emissivity (highly reflective) exterior surfaces such as aluminum foil. Lower thermal conductivity, or higher R-values, can be achieved by allowing an air gap between the surface of the structure and the aluminium foil. The air gap will act an heat pocket where heat will accumulate instead of being circulation inside your structure. Trapped air has its own R value. The R value of trapped air depends on how much gap is between the insulation material an the structure. A wider gap will produce a greater R value and a narrower. Gap will produce a smaller R value. Air by itself has no R value; only trapped air will produce an R value. However, if you allow a very wide gap, the air will not be trapped and may reduce your R value and cause an opposite result. The R-value is a measure of an insulation sample’s ability to reduce the rate of heat flow under specified test conditions. The primary mode of heat transfer impeded by insulation is conduction, but insulation also reduces heat loss by all three heat transfer modes: conduction, convection, and radiation. The primary means of heat loss across an uninsulated air-filled space is natural convection, which occurs because of changes in air density with temperature. Insulation greatly retards natural convection making the primary mode of heat transfer conduction. To find the heat loss per square meter, simply divide the temperature difference by the R value. If the interior of a home is at 20 °C, and the roof cavity is at 10 °C, the temperature difference is 10 C° (= 10 K difference). Assuming a ceiling insulated to R-2 (R = 2.0 m2K/W), energy will be lost at a rate of 10 K/2 K·m2/W = 5 watts for every square meter of ceiling. Doubling the thickness of the insulation material or even doubling the thickness of the trapped air layer doubles the R value. This does not hold for compressed bats of glass wool because compressing the bats does not proportionally increase the r value. Furthermore, doubling the thickness of the Silver Foil Bubble Insulation does not double the R value of the insulation material. The main feature of the Silver Backed Bubble Insulation is its reflective nature and not its thickness. To Double the R value of the Foil Bubble Insulation you will need to create a heat pocket which hads it s own R value that can be added to the R value of the Foil Insulation. As an example, the if Foil Bubble Insulation has an R value of r2 and the. Heat pocket has an R value of R 1,5, both R value are added together to achieve an R value of R3.5 in SI units or R19 in United States standards. As discussed earlier porous material such as foam and bats does not allow the full potential of trapped air to be established and will not give you the proportional R value relative to thickness. In calculating the R-value of a multi-layered installation, the R-values of the individual layers are added:[10]. R-value(outside air film) + R-value(brick) + R-value(sheathing) + R-value(insulation) + R-value(plasterboard) + R-value(inside air film) = R-value(total). To account for other components in a wall such as framing, an area-weighted average R-value of the whole wall may be calculated. For the most part, testing the R-value of insulation is done at a steady temperature, usually about 70 °F (21 °C) with no surrounding air movement. Since these are ideal conditions, the listed R-value for insulation will almost certainly be higher than it would be in actual use, because most situations with insulation are under different conditions. Some types of foam insulation, such as polyurethane and polyisocyanurate are blown with heavy gases such as chlorofluorocarbons (CFC) or hydrochlorofluorocarbons (HFCs). However, over time a small amount of these gases diffuse out of the foam and are replaced by air, thus reducing the effective R-value of the product. This has led to controversy as how to rate the insulation of these products. Many manufacturers will rate the R-value at the time of manufacture; critics argue that a more fair assessment would be its settled value. [citation needed] The foam industrywhen? Adopted the LTTR (Long-Term Thermal Resistance) method, [14] which rates the R-value based on a 15 year weighted average. However, the LTTR effectively provides only an eight-year aged R-value, short in the scale of a building that may have a lifespan of 50 to 100 years. Note that these examples use the non-SI definition and/or given for a 1 inch (25.4 mm) thick sample. Vacuum insulated panels have the highest R-value (approximately R-45 per inch in American customary units); aerogel has the next highest R-value (about R-10-30 per inch), followed by isocyanurate and phenolic foam insulations with, R-8.3 and R-7 per inch, respectively. They are followed closely by polyurethane and polystyrene insulation at roughly R-6 and R-5 per inch. Loose cellulose, fiberglass (both blown and in batts), and rock wool (both blown and in batts) all possess an R-value of roughly R–2.5 to R–4 per inch. Straw bales perform at about R-1.5. However, typical straw bale houses have very thick walls and thus are well insulated. Snow is roughly R-1. The effective thermal resistance of an enclosed air cavity is strongly influenced by radiative heat transfer and distance between the two surfaces. The insulation comes in 1,500 mm wide or 750 mm wide – total 75 Square meters. To check my other items go to. Please Note: Due to the bulky size of this insulation, every 75 Square Meter comes in 2 rolls of 37.5 Square meters each – 2 rolls of 25 meter long 1,500 mm wide or alternatively 2 rolls of 50 meter long 750 mm wide depending on availability. For specific sizes and availability, please contact me. The courier will not transport sizes larger than the above but you may order any amount you want. Public holidays and weekends excluded. However, there is no guarantee that you will receive your parcel by the estimated date. The most economical method. If you wish to have your item delivered or handled in a special manner, let me know and I will inform you if there is any additional charge. If you live in a remote location with no courier service, let me know. Delays may be experienced in case of work overload, postal or courier. Delays, public holidays and weekends, or shortage of stock. If premises unattended, leave in a secure location. If premises unattended, place a card in the mailbox and leave parcel at nearest collection point. The parcel shall be deemed to have been delivered. If the parcel is sent by courier, a signature is usually required. You can select that the courier leaves the parcel. If it is not safe to leave the parcel by Your front door, then you will need to sign for it. All parcels will be securely packaged. For its loss or damage. Otherwords, all care taken and no responsibility accepted. No responsibility can be taken if you fail to provide a telephone number. Please note, I assume no responsibility if the item is delayed, lost or damaged n transit. No compensation will be paid until such investigation has been concluded. You will also need to arrange for your own packaging. International Buyers – Please Note. I strive to please my fellow eBayers. If you have any issue with the item, let me know. No other warranties either expressed or implied are offered. You may find similar items cheaper with other sellers or retailers. I also rely on sighted assistants to help with the pictures and description. If you prefer to trade with a behemoth, please go elsewhere. From time to time I offer the same item cheaper for a limited period. The description of the items is as provided by the principal sellers and believed to be reliable. All feedback will be reciprocated. If you are happy with my service, tell the whole world, if you are not happy, tell me. If you have any issue with the item, contact me first before you post negative or neutral feedback. Issues can be resolved amicably. Leaving damaging feedback before your attempt to resolve any issue first will be deemed as defamatory and in contravention of the terms and conditions and will be dealt with accordingly. The bad Karma will result in proceedings for the removal of such feedback and will give rise of a liquidated claim for damages. Any unwarranted negative or neutral feedback will be removed using legal processes and may give rise to a liquidated claim for defamation or/ and breach of contract. All issues can be resolved amicably. An issue, contact me first. If you have any issues with your item, let me know and I will be happy to rectify any problem. If you post negative or neutral feedback without first letting me know of your intention to post such feedback will be deemed defamatory and may give rise to proceedings for defamation and/or breach of contract and will give rise to a liquidated claim for damages. If you have in issue, it would be quicker to contact me first and I will do my utmost to help you. If you do not wish to have feedback posted for you – for privacy reasons or otherwise – just let me know and I will not post feedback for you or simply do not post feedback for me. All brand names & trademarks are the property of their respective holders and are referred to here for descriptive purpose only. The listed brand names and model designations are intended only to show the compatibility of these products with various products. Pictures are for descriptive purposes only. All dimensions and measurements are approximate. Colour is as shown unless otherwise stated. Colour may vary depending on lighting, your computer screen resolution or angle of viewing. Please exercise care when you open your package when you receive it. Do not slash the packing material with a knife as to damage the contents of the package. Open carefully so you don’t drop the contents in case of fragile or breakable items. If the information is not correct, please provide your correct contact information. You agree to abide by the herein Terms & Conditions and any further amendments. Any dispute arising out of this. Agreement or the interpretation thereof. Shall be decided and. Settled in accordance with the laws and statues of the State of New South Wales, Australia. The parties agree that the venue shall be Sydney, New south Wales. Cash in person or Bank Deposit. This item is in the category “Home & Garden\Other Home & Garden”. The seller is “eddiesolomon777″ and is located in this country: AU. This item can be shipped worldwide.
  • Product Type: Silver Foil Bubble Wrap Insulation
  • Modified Item: No
  • Style: ROLL
  • Custom Bundle: No
  • Type: INSULATION
  • MPN: SFBI2
  • Room: ALL ROOMS
  • Brand: INSULATION ACADEMY
  • UPC: 722197213239

Heavy Duty Double Foil Air Bubble Silver Cell Insulation 75 Sq M Free Shipping

HEAVY DUTY DOUBLE FOIL AIR BUBBLE CELL INSULATION 75 SQM Extra Thick -FREE SH

Posted on by
HEAVY_DUTY_DOUBLE_FOIL_AIR_BUBBLE_CELL_INSULATION_75_SQM_Extra_Thick_FREE_SH_01_dx HEAVY DUTY DOUBLE FOIL AIR BUBBLE CELL INSULATION 75 SQM Extra Thick -FREE SH
HEAVY DUTY DOUBLE FOIL AIR BUBBLE CELL INSULATION 75 SQM Extra Thick -FREE SH
HEAVY DUTY DOUBLE FOIL AIR BUBBLE CELL INSULATION 75 SQM Extra Thick -FREE SH
HEAVY DUTY DOUBLE FOIL AIR BUBBLE CELL INSULATION 75 SQM Extra Thick -FREE SH
HEAVY DUTY DOUBLE FOIL AIR BUBBLE CELL INSULATION 75 SQM Extra Thick -FREE SH
HEAVY DUTY DOUBLE FOIL AIR BUBBLE CELL INSULATION 75 SQM Extra Thick -FREE SH
HEAVY DUTY DOUBLE FOIL AIR BUBBLE CELL INSULATION 75 SQM Extra Thick -FREE SH

HEAVY DUTY DOUBLE FOIL AIR BUBBLE CELL INSULATION 75 SQM Extra Thick -FREE SH
Thank you for viewing my listing. DOUBLE SIDED SILVER FOIL. TWO LAYERS OF FOIL. REDUCE RADIANT HEAT TRANSFER. IDEAL FOR HOT OR COLD CLIMATE. 75 SQUARE METERS (825 SQUARE FEET). 20 MM (3/4) DIAMETER BUBBLES. 8 MM THICK (3/16) BUBBLES. TWO LAYERS OF ALUMINUM FOIL. THIS IS THE EXTRA THICK 8MM THICK – 20 MM DIAMETER BUBBLES FOR EXTRA PROTECTION. Call Eddie Solomon if you have any question. Please Note: this product does not comply with Australian Standards nor the Building Code but it is tested by Australian CSIRO and has been used widely for home insulation. TO VIEW ALL FOIL BUBBLE INSULATION. SILVER FOIL BUBBLE INSULATION. Double Foil Insulation is available in 75 Square Meters rolls – 1,500 mm wide x 50 Meters long. It consists of a layer of polyethylene bubbles that is sandwiched between two layers of 99% pure aluminum radiant barrier foil. This style can be used in a variety of applications because it’s light weight and easy to handle yet provides superior protection. The bubble center creates maximum R-Value and the reflective foil on both sides allow it to reflect 97% of radiant heat away from a structure on the outside and back in on a structure from the inside. This is why it works effectively in both hot and cold climates. Double Foil Reflective Insulation is a versatile insulation consisting of an 4.8 mm thick – 10 mm diameter layer of polyethylene bubbles sandwiched between two sheets of highly reflective, 99% aluminum. Reflective Bubble Insulation provides superior reflectivity of radiant heat while providing protection against conductive heat gain and loss as well as performing as a vapor barrier. Nominal Thickness 1/4 – 0.6 mm. Weight 0.5 oz / sq. Ft – 160 g/sq m. Temperature Range – ASTM C411 -50 F to 180 F (-45 c to 82 c). Flame Spread (ASTM E84-05) 5. Smoke Development (ASTM E84-05) 5. Emissivity – ASTM C1371 0.03-0.04. Reflectivity – ASTM 3903 0.96-0.97. Water Vapor Permeance-ASTM E96. Flexibility – No Cracking. Resistant to Fungi and Bacteria Does not promote growth. ADVANTAGES OF THIS PRODUCT. Very effective in warmer climates. No change to thermal performance over time due to compaction, disintegration or moisture absorption. Thin sheets takes up less room than bulk insulation. Can act as a vapor barrier. Will not mold or mildew. Radon retarder, will limit radon penetration through the floor. This is a high quality industrial strength Double Foil Insulation Bubble Wrap. Long lasting, heavy duty nylon barrier layer to increase longevity. Bubble Wrap is Lightweight and easy to use. It is an inexpensive solution to your insulation needs. This 75 Square meter Silver Insulation Foil Bubble Wrap usually comes in rolls of 1,500 mm wide. However, it may come in other widths totalling 75 Square meter depending on availability. Our standard single and double bubble foil insulation is. Silver foil Available in a range of widths, from. 375 mm 15″ to 1,500 mm (60″), and lengths. We offer double-sided Silver. Aluminium products, as well as products covered with Silver Foil. On one side and white polyethylene on the other. This durable bubble insulation will withstand temperatures between -50 degrees Celsius. And 82 degrees Celsius (180 degrees Fahrenheit), making it ideal for both attic and flooring installations. Be sure to check out our silver Foil Aluminium. This is the best tape for bubble foil insulation because it ensures the continuity of the reflective surface, which is essential for getting the most from your installation. Radiant floor heating has been in use for centuries and radiant barriers help to retain the heat generated by the radiant heating system blocking it from escaping into the ground. Silver foil bubble Wrap. Insulation is extremely tough and pliable, easy to install, and is an excellent vapor barrier for all your radiant floor heating applications, thus greatly reducing your electricity or gas bills. Silver Foil Bubble wrap. Insulation installed in crawl spaces below a building structure reflect the heat flows that are flowing downward from the flooring back up into the flooring at a 95-97% rate providing increased comfort and heat retention. The temperature of the cold floors which cause cold feet will be raised while your heating bill is reduced, providing for increased comfort. As heat is reflected back into the living area, it warms other objects which then radiate heat back into the room, further increasing your living comfort. Metal & Steel Buildings. Temperature sensitive storage areas. Silver foil Bubble Wrap. Insulation applications are only limited by your imagination. The main feature of this insulation is its reflective nature and not the thickness of the material. It has a nominal thickness of 4.8 mm and easy to handle. We can also custom make any combination to suit your requirements. You can have foam sandwiched between two layers of Silver foil, Or thicker bubbles between tow layers of foil, or any combination you require. Please note custom made insulation attracts minimum order of 1,500 Square meters. Custom orders are final. All the insulation is made right here in Australia with the highest standard of material and manufacture. The following Test Report conducted by the Australian CSIRO on the single Foil Bubble Insulation. This listing is for the Double Foil Bubble Insulation which commands a higher insulation quality tham the single. CSIRO- Materials Science & Engineering. (ABN: 41 687 119 230). Page 1 of 1. Sample Description: silver insulation material designed for pallet protection. At an ambient temperature of 23.1ºC – difference from face to back 2.4ºC. At an ambient temperature of 28.6ºC – difference from face to back 5.1ºC. OF THE INSULATIVE EFFECTIVENESS OF SINGLE-SIDED 10 MILLIMETRE BUBBLE FILM (4.8 mm Thick). LAMINATED WITH METALLISED P. THE TRUTH ABOUT R VALUE. Around most of the world, R-values are given in SI units, typically square-metre kelvin per watt or m2·K/W (or equally, m2·°C/W). In the United States customary units, R-values are given in units of ft2·°F·hr/Btu. It is particularly easy to confuse SI and US R-values, because R-values both in the US and elsewhere are often cited without their units, e. Usually, however, the correct units can be inferred from the context and from the magnitudes of the values. United States R-values are approximately six times SI R-values. The conversion between SI and US units of R-value is 1 h·ft2·°F/Btu = 0.176110 K·m2/W, or 1 K·m2/W = 5.678263 h·ft2·°F/Btu. As an example an R11 in the United States is approximately R2 in SI units in Europe, Australia and the rest of the world. An R value advertised by a United States merchant may appear more appealing as the US R value is 6 times higher than SI values used in the rest of the world. It does not mean that a US R value is more effective than An R value used in Europe, Australia or the rest of the world. Do not rely on the R value provided by the supplier as the R value may increase or decrease depending on the application. Furthermore, the actual R value of the insulation depends entirely on the application and how you apply the insulation. An R 2 value may increase or decrease depending on how the insulation is applied. With the Silver Foil bubble Insulation you will need an air pocket between the surface. Of the structure you are insulating. And the insulation material. The air pocket has its own r value depending on the width of the air pocket thus increasing the R value of the insulation material. Conversely, if you apply the insulation material directly on the surface of the structure will defeat the purpose of insulation because the insulation material will act as a heat conductor and will end up heating the premises in the hot summer and will also be counterproductive in winter. Radiation is minimized by low emissivity (highly reflective) exterior surfaces such as aluminum foil. Lower thermal conductivity, or higher R-values, can be achieved by allowing an air gap between the surface of the structure and the aluminium foil. The air gap will act an heat pocket where heat will accumulate instead of being circulation inside your structure. Trapped air has its own R value. The R value of trapped air depends on how much gap is between the insulation material an the structure. A wider gap will produce a greater R value and a narrower. Gap will produce a smaller R value. Air by itself has no R value; only trapped air will produce an R value. However, if you allow a very wide gap, the air will not be trapped and may reduce your R value and cause an opposite result. The R-value is a measure of an insulation sample’s ability to reduce the rate of heat flow under specified test conditions. The primary mode of heat transfer impeded by insulation is conduction, but insulation also reduces heat loss by all three heat transfer modes: conduction, convection, and radiation. The primary means of heat loss across an uninsulated air-filled space is natural convection, which occurs because of changes in air density with temperature. Insulation greatly retards natural convection making the primary mode of heat transfer conduction. To find the heat loss per square meter, simply divide the temperature difference by the R value. If the interior of a home is at 20 °C, and the roof cavity is at 10 °C, the temperature difference is 10 C° (= 10 K difference). Assuming a ceiling insulated to R-2 (R = 2.0 m2K/W), energy will be lost at a rate of 10 K/2 K·m2/W = 5 watts for every square meter of ceiling. Doubling the thickness of the insulation material or even doubling the thickness of the trapped air layer doubles the R value. This does not hold for compressed bats of glass wool because compressing the bats does not proportionally increase the r value. Furthermore, doubling the thickness of the Silver Foil Bubble Insulation does not double the R value of the insulation material. The main feature of the Silver Backed Bubble Insulation is its reflective nature and not its thickness. To Double the R value of the Foil Bubble Insulation you will need to create a heat pocket which hads it s own R value that can be added to the R value of the Foil Insulation. As an example, the if Foil Bubble Insulation has an R value of r2 and the. Heat pocket has an R value of R 1,5, both R value are added together to achieve an R value of R3.5 in SI units or R19 in United States standards. As discussed earlier porous material such as foam and bats does not allow the full potential of trapped air to be established and will not give you the proportional R value relative to thickness. In calculating the R-value of a multi-layered installation, the R-values of the individual layers are added:[10]. R-value(outside air film) + R-value(brick) + R-value(sheathing) + R-value(insulation) + R-value(plasterboard) + R-value(inside air film) = R-value(total). To account for other components in a wall such as framing, an area-weighted average R-value of the whole wall may be calculated. For the most part, testing the R-value of insulation is done at a steady temperature, usually about 70 °F (21 °C) with no surrounding air movement. Since these are ideal conditions, the listed R-value for insulation will almost certainly be higher than it would be in actual use, because most situations with insulation are under different conditions. Some types of foam insulation, such as polyurethane and polyisocyanurate are blown with heavy gases such as chlorofluorocarbons (CFC) or hydrochlorofluorocarbons (HFCs). However, over time a small amount of these gases diffuse out of the foam and are replaced by air, thus reducing the effective R-value of the product. This has led to controversy as how to rate the insulation of these products. Many manufacturers will rate the R-value at the time of manufacture; critics argue that a more fair assessment would be its settled value. [citation needed] The foam industrywhen? Adopted the LTTR (Long-Term Thermal Resistance) method, [14] which rates the R-value based on a 15 year weighted average. However, the LTTR effectively provides only an eight-year aged R-value, short in the scale of a building that may have a lifespan of 50 to 100 years. Note that these examples use the non-SI definition and/or given for a 1 inch (25.4 mm) thick sample. Vacuum insulated panels have the highest R-value (approximately R-45 per inch in American customary units); aerogel has the next highest R-value (about R-10-30 per inch), followed by isocyanurate and phenolic foam insulations with, R-8.3 and R-7 per inch, respectively. They are followed closely by polyurethane and polystyrene insulation at roughly R-6 and R-5 per inch. Loose cellulose, fiberglass (both blown and in batts), and rock wool (both blown and in batts) all possess an R-value of roughly R–2.5 to R–4 per inch. Straw bales perform at about R-1.5. However, typical straw bale houses have very thick walls and thus are well insulated. Snow is roughly R-1. The effective thermal resistance of an enclosed air cavity is strongly influenced by radiative heat transfer and distance between the two surfaces. All quality products at bargain prices. Occasionally, I list the same item with discounted prices for a limited time. Please Note: Due to the bulky size of this insulation, the 75 Square Meters are sent as follows. 1 Roll of 75 square meters – 1,500 mm wide 50 m long. 2 Rolls of 37.5 Square meters – 1,500 mm wide 25 m long each. 2 rolls of 37.5 Square meters each – 750 mm wide 50 m long. If you want your order in any specific combination, please let me know. Public holidays and weekends excluded. However, there is no guarantee that you will receive your parcel by the estimated date. The most economical method. If you wish to have your item delivered or handled in a special manner, let me know and I will inform you if there is any additional charge. If you live in a remote location with no courier service, let me know. Delays may be experienced in case of work overload, postal or courier. Delays, public holidays and weekends, or shortage of stock. If premises unattended, leave in a secure location. If premises unattended, place a card in the mailbox and leave parcel at nearest collection point. The parcel shall be deemed to have been delivered. If the parcel is sent by courier, a signature is usually required. You can select that the courier leaves the parcel. If it is not safe to leave the parcel by Your front door, then you will need to sign for it. All parcels will be securely packaged. For its loss or damage. Otherwords, all care taken and no responsibility accepted. No responsibility can be taken if you fail to provide a telephone number. Please note, I assume no responsibility if the item is delayed, lost or damaged n transit. No compensation will be paid until such investigation has been concluded. You will also need to arrange for your own packaging. International Buyers – Please Note. I strive to please my fellow eBayers. If you have any issue with the item, let me know. Errors & Omissions Excluded. No other warranties either expressed or implied are offered. You may find similar items cheaper with other sellers or retailers. I also rely on sighted assistants to help with the pictures and description. If you prefer to trade with a behemoth, please go elsewhere. From time to time I offer the same item cheaper for a limited period. The description of the items is as provided by the principal sellers and believed to be reliable. All feedback will be reciprocated. If you are happy with my service, tell the whole world, if you are not happy, tell me. If you have any issue with the item, contact me first before you post negative or neutral feedback. Issues can be resolved amicably. Leaving damaging feedback before your attempt to resolve any issue first will be deemed as defamatory and in contravention of the terms and conditions and will be dealt with accordingly. The bad Karma will result in proceedings for the removal of such feedback and will give rise of a liquidated claim for damages. Any unwarranted negative or neutral feedback will be removed using legal processes and may give rise to a liquidated claim for defamation or/ and breach of contract. All issues can be resolved amicably. An issue, contact me first. If you have any issues with your item, let me know and I will be happy to rectify any problem. If you post negative or neutral feedback without first letting me know of your intention to post such feedback will be deemed defamatory and may give rise to proceedings for defamation and/or breach of contract and will give rise to a liquidated claim for damages. If you have in issue, it would be quicker to contact me first and I will do my utmost to help you. If you do not wish to have feedback posted for you – for privacy reasons or otherwise – just let me know and I will not post feedback for you or simply do not post feedback for me. All brand names & trademarks are the property of their respective holders and are referred to here for descriptive purpose only. The listed brand names and model designations are intended only to show the compatibility of these products with various products. Pictures are for descriptive purposes only. All dimensions and measurements are approximate. Colour is as shown unless otherwise stated. Colour may vary depending on lighting, your computer screen resolution or angle of viewing. Please exercise care when you open your package when you receive it. Do not slash the packing material with a knife as to damage the contents of the package. Open carefully so you don’t drop the contents in case of fragile or breakable items. If the information is not correct, please provide your correct contact information. You agree to abide by the herein Terms & Conditions and any further amendments. Any dispute arising out of this. Agreement or the interpretation thereof. Shall be decided and. Settled in accordance with the laws and statues of the State of New South Wales, Australia. The parties agree that the venue shall be Sydney, New south Wales. This item is in the category “Home & Garden\Other Home & Garden”. The seller is “eddiesolomon777″ and is located in this country: AU. This item can be shipped worldwide.
  • Product Type: Silver Foil Bubble Wrap Insulation
  • Modified Item: No
  • Style: Double Sided Foil
  • Custom Bundle: No
  • Type: Roll
  • MPN: SFBI2
  • Room: ALL ROOMS
  • Brand: EDDIE SOLOMON
  • UPC: 722197213819

HEAVY DUTY DOUBLE FOIL AIR BUBBLE CELL INSULATION 75 SQM Extra Thick -FREE SH
Category: heavy | Tags: , , , , , , , , ,

Silver Foil Cell Air Bubble Insulation 40 M L 750mm W Australian Csiro Tested

Posted on by
Silver_Foil_Cell_Air_Bubble_Insulation_40_M_L_750mm_W_Australian_Csiro_Tested_01_ttb Silver Foil Cell Air Bubble Insulation 40 M L 750mm W Australian Csiro Tested
Silver Foil Cell Air Bubble Insulation 40 M L 750mm W Australian Csiro Tested
Silver Foil Cell Air Bubble Insulation 40 M L 750mm W Australian Csiro Tested
Silver Foil Cell Air Bubble Insulation 40 M L 750mm W Australian Csiro Tested
Silver Foil Cell Air Bubble Insulation 40 M L 750mm W Australian Csiro Tested
Silver Foil Cell Air Bubble Insulation 40 M L 750mm W Australian Csiro Tested

Silver Foil Cell Air Bubble Insulation 40 M L 750mm W Australian Csiro Tested
Thank you for viewing my listing. REDUCE RADIANT HEAT TRANSFER. IDEAL FOR HOT & COLD CLIMATE. ALSO AVAILABLE THE DOUBLE FOIL BUBBLE INSULATION. VIEW MY OTHER LISTINGS FOR THE COMPLETE RANGE. TESTED BY AUSTRALIAN CSIRO. 750 MM WIDE (30). 40 METRES LONG (130 FEET). 10 MM (3/8) DIAMETER BUBBLES. ALSO AVAULABLE THE EXTRA HEAVY DUTY EXTRA THICK FIRE RESISTANT. TO VIEW ALL FOIL BUBBLE INSULATION. THE CHINESE AND IMPORTED INSULATION COMES IN ROLLS OF 1,200MM WIDE. THIS AUSTRALIAN MADE PRODUCT COMES IN ROLLS OF 1,500MM, 750MM. Call Eddie Solomon if you have any question. SINGLE SILVER FOIL BU. Single Foil Insulation is available in various size rolls. It consists of a layer of polyethylene bubbles and a layer of 99% pure aluminum radiant barrier foil. This style can be used in a variety of applications because it’s light weight and easy to handle yet provides superior protection. The bubble layer creates maximum R-Value and the reflective foil allows it to reflect 97% of radiant heat away from a structure on the outside and back in on a structure from the inside. This is why it works effectively in both hot and cold climates. Single Foil Reflective Insulation is a versatile insulation consisting of a – 10 mm diameter -layer of polyethylene bubbles backed by a sheet of highly reflective, 99% aluminum. Reflective Bubble Insulation provides superior reflectivity of radiant heat while providing protection against conductive heat gain and loss as well as performing as a vapor barrier. Also available double Foil Insulation Bubble Wrap for ultimate protection and higher R value. Also available rolls of 75 Square Meters, 450 Square Meters, 600 Square Meters in both single Foil or Heavy Duty Double Foil or Extra Heavy Duty Double Foil Extra thick bubbles. Foil bubble insulation is ideal for metal building and commercial roof applications where the product will be seen and where aesthetics are important. The reflective surface can even make an area brighter, effectively cutting down on the electricity needed to meet lighting requirements. Foil bubble wrap can also be applied to windows to keep out the glare of the sun, and also to keep heat in or out depending on the weather. This is Foil lined Bubble Wrap on one side. Also available Silver Foil Insulation reinforced Tape. This listing is for Single Foil Bubble Insulation. Double Foil bubble Insulation as also available. Minimum order for Double Foil is 75 Sq M. ADVANTAGES OF THIS PRODUCT. Very effective in warmer climates. No change thermal performance over time due to compaction, disintegration or moisture absorption. Thin sheets takes up less room than bulk insulation. Can act as a vapor barrier. Will not mold or mildew. Radon retarder, will limit radon penetration through the floor. For a demonstration on the use of Silver Foil Bubble Insulation, go to the following links. Our standard single and double bubble foil insulation is. Silver foil Available in a range of widths, from. 375 mm 15″ to 1,500 mm (60″), and lengths. We offer double-sided Silver. Aluminium products, as well as products covered with Silver Foil. On one side and white polyethylene on the other. This durable bubble insulation will withstand temperatures between -50 degrees Celsius. And 82 degrees Celsius (180 degrees Fahrenheit), making it ideal for both attic and flooring installations. Be sure to check out our silver Foil Aluminium. This is the best tape for bubble foil insulation because it ensures the continuity of the reflective surface, which is essential for getting the most from your installation. Radiant floor heating has been in use for centuries and radiant barriers help to retain the heat generated by the radiant heating system blocking it from escaping into the ground. Silver foil bubble Wrap. Insulation is extremely tough and pliable, easy to install, and is an excellent vapor barrier for all your radiant floor heating applications, thus greatly reducing your electricity or gas bills. Silver Foil Bubble wrap. Insulation installed in crawl spaces below a building structure reflect the heat flows that are flowing downward from the flooring back up into the flooring at a 95-97% rate providing increased comfort and heat retention. The temperature of the cold floors which cause cold feet will be raised while your heating bill is reduced, providing for increased comfort. As heat is reflected back into the living area, it warms other objects which then radiate heat back into the room, further increasing your living comfort. Metal & Steel Buildings. Temperature sensitive storage areas. Wrapping Chocolates, Candy and Food for freshness. Silver foil Bubble Wrap. Insulation applications are only limited by your imagination. CSIRO- Materials Science & Engineering. (ABN: 41 687 119 230). Page 1 of 1. Sample Description: silver insulation material designed for pallet protection. At an ambient temperature of 23.1ºC – difference from face to back 2.4ºC. At an ambient temperature of 28.6ºC – difference from face to back 5.1ºC. OF THE INSULATIVE EFFECTIVENESS OF SINGLE-SIDED 10 MILLIMETRE BUBBLE FILM (4.8 mm Thick). LAMINATED WITH METALLISED P. The above test report conducted by the CSIRO relates only to the single foil insulation. The double foil provides even more superior features and a higher r value. The main feature of this insulation is its reflective nature and not the thickness of the material. It has a nominal thickness of 4.8 mm and easy to handle. We can also custom make any combination to suit your requirements. You can have foam sandwiched between two layers of Silver foil, Or thicker bubbles between tow layers of foil, or any combination you require. Please note custom made insulation attracts minimum order of 1,500 Square meters. Custom orders are final. All the insulation is made right here in Australia with the highest standard of material and manufacture. This is a high quality industrial strength Foil Bubble Wrap. Long lasting, heavy duty nylon barrier layer to increase longevity. Bubble Wrap is Lightweight and easy to use. It is an inexpensive solution to your insulation needs. THE TRUTH ABOUT R VALUE. Around most of the world, R-values are given in SI units, typically square-metre kelvin per watt or m2·K/W (or equally, m2·°C/W). In the United States customary units, R-values are given in units of ft2·°F·hr/Btu. It is particularly easy to confuse SI and US R-values, because R-values both in the US and elsewhere are often cited without their units, e. Usually, however, the correct units can be inferred from the context and from the magnitudes of the values. United States R-values are approximately six times SI R-values. The conversion between SI and US units of R-value is 1 h·ft2·°F/Btu = 0.176110 K·m2/W, or 1 K·m2/W = 5.678263 h·ft2·°F/Btu. As an example an R11 in the United States is approximately R2 in SI units in Europe, Australia and the rest of the world. An R value advertised by a United States merchant may appear more appealing as the US R value is 6 times higher than SI values used in the rest of the world. It does not mean that a US R value is more effective than An R value used in Europe, Australia or the rest of the world. Do not rely on the R value provided by the supplier as the R value may increase or decrease depending on the application. Furthermore, the actual R value of the insulation depends entirely on the application and how you apply the insulation. An R 2 value may increase or decrease depending on how the insulation is applied. With the Silver Foil bubble Insulation you will need an air pocket between the surface of the structure you are insulating and the insulation material. The air pocket has its own r value depending on the width of the air pocket thus increasing the R value of the insulation material. Conversely, if you apply the insulation material directly on the surface of the structure will defeat the purpose of insulation because the insulation material will act as a heat conductor and will end up heating the premises in the hot summer and will also be counterproductive in winter. Radiation is minimized by low emissivity (highly reflective) exterior surfaces such as aluminum foil. Lower thermal conductivity, or higher R-values, can be achieved by allowing an air gap between the surface of the structure and the aluminium foil. The air gap will act an heat pocket where heat will accumulate instead of being circulation inside your structure. Trapped air has its own R value. The R value of trapped air depends on how much gap is between the insulation material an the structure. A wider gap will produce a greater R value and a narrower gap will produce a smaller R value. Air by itself has no R value; only trapped air will produce an R value. However, if you allow a very wide gap, the air will not be trapped and may reduce your R value and cause an opposite result. The R-value is a measure of an insulation sample’s ability to reduce the rate of heat flow under specified test conditions. The primary mode of heat transfer impeded by insulation is conduction, but insulation also reduces heat loss by all three heat transfer modes: conduction, convection, and radiation. The primary means of heat loss across an uninsulated air-filled space is natural convection, which occurs because of changes in air density with temperature. Insulation greatly retards natural convection making the primary mode of heat transfer conduction. To find the heat loss per square meter, simply divide the temperature difference by the R value. If the interior of a home is at 20 °C, and the roof cavity is at 10 °C, the temperature difference is 10 C° (= 10 K difference). Assuming a ceiling insulated to R-2 (R = 2.0 m2K/W), energy will be lost at a rate of 10 K/2 K·m2/W = 5 watts for every square meter of ceiling. Doubling the thickness of the insulation material or even doubling the thickness of the trapped air layer doubles the R value. This does not hold for compressed bats of glass wool because compressing the bats does not proportionally increase the r value. Furthermore, doubling the thickness of the Silver Foil Bubble Insulation does not double the R value of the insulation material. The main feature of the Silver Backed Bubble Insulation is its reflective nature and not its thickness. To Double the R value of the Foil Bubble Insulation you will need to create a heat pocket which hads it s own R value that can be added to the R value of the Foil Insulation. As an example, the if Foil Bubble Insulation has an R value of r2 and the heat pocket has an R value of R 1,5, both R value are added together to achieve an R value of R3.5 in SI units or R19 in United States standards. As discussed earlier porous material such as foam and bats does not allow the full potential of trapped air to be established and will not give you the proportional R value relative to thickness. In calculating the R-value of a multi-layered installation, the R-values of the individual layers are added:[10]. R-value(outside air film) + R-value(brick) + R-value(sheathing) + R-value(insulation) + R-value(plasterboard) + R-value(inside air film) = R-value(total). To account for other components in a wall such as framing, an area-weighted average R-value of the whole wall may be calculated. For the most part, testing the R-value of insulation is done at a steady temperature, usually about 70 °F (21 °C) with no surrounding air movement. Since these are ideal conditions, the listed R-value for insulation will almost certainly be higher than it would be in actual use, because most situations with insulation are under different conditions. Some types of foam insulation, such as polyurethane and polyisocyanurate are blown with heavy gases such as chlorofluorocarbons (CFC) or hydrochlorofluorocarbons (HFCs). However, over time a small amount of these gases diffuse out of the foam and are replaced by air, thus reducing the effective R-value of the product. This has led to controversy as how to rate the insulation of these products. Many manufacturers will rate the R-value at the time of manufacture; critics argue that a more fair assessment would be its settled value. [citation needed] The foam industrywhen? Adopted the LTTR (Long-Term Thermal Resistance) method, [14] which rates the R-value based on a 15 year weighted average. However, the LTTR effectively provides only an eight-year aged R-value, short in the scale of a building that may have a lifespan of 50 to 100 years. Note that these examples use the non-SI definition and/or given for a 1 inch (25.4 mm) thick sample. Vacuum insulated panels have the highest R-value (approximately R-45 per inch in American customary units); aerogel has the next highest R-value (about R-10-30 per inch), followed by isocyanurate and phenolic foam insulations with, R-8.3 and R-7 per inch, respectively. They are followed closely by polyurethane and polystyrene insulation at roughly R-6 and R-5 per inch. Loose cellulose, fiberglass (both blown and in batts), and rock wool (both blown and in batts) all possess an R-value of roughly R–2.5 to R–4 per inch. Straw bales perform at about R-1.5. However, typical straw bale houses have very thick walls and thus are well insulated. Snow is roughly R-1. The effective thermal resistance of an enclosed air cavity is strongly influenced by radiative heat transfer and distance between the two surfaces. All quality products at bargain prices. Occasionally, I list the same item with discounted prices for a limited time. To check my other items go to. Please Note: This insulation comes in 50 meter long rolls. This may come in one or multiple rolls totalling 40 meters. Public holidays and weekends excluded. However, there is no guarantee that you will receive your parcel by the estimated date. The most economical method. If you wish to have your item delivered or handled in a special manner, let me know and I will inform you if there is any additional charge. If you live in a remote location with no courier service, let me know. Delays may be experienced in case of work overload, postal or courier. Delays, public holidays and weekends, or shortage of stock. If premises unattended, leave in a secure location. If premises unattended, place a card in the mailbox and leave parcel at nearest collection point. The parcel shall be deemed to have been delivered. If the parcel is sent by courier, a signature is usually required. You can select that the courier leaves the parcel. If it is not safe to leave the parcel by Your front door, then you will need to sign for it. All parcels will be securely packaged. For its loss or damage. Otherwords, all care taken and no responsibility accepted. No responsibility can be taken if you fail to provide a telephone number. Please note, I assume no responsibility if the item is delayed, lost or damaged n transit. No compensation will be paid until such investigation has been concluded. You will also need to arrange for your own packaging. International Buyers – Please Note. I strive to please my fellow eBayers. If you have any issue with the item, let me know. Errors & Omissions Excluded. No other warranties either expressed or implied are offered. You may find similar items cheaper with other sellers or retailers. I also rely on sighted assistants to help with the pictures and description. If you prefer to trade with a behemoth, please go elsewhere. From time to time I offer the same item cheaper for a limited period. The description of the items is as provided by the principal sellers and believed to be reliable. All feedback will be reciprocated. If you are happy with my service, tell the whole world, if you are not happy, tell me. If you have any issue with the item, contact me first before you post negative or neutral feedback. Issues can be resolved amicably. Leaving damaging feedback before your attempt to resolve any issue first will be deemed as defamatory and in contravention of the terms and conditions and will be dealt with accordingly. The bad Karma will result in proceedings for the removal of such feedback and will give rise of a liquidated claim for damages. Any unwarranted negative or neutral feedback will be removed using legal processes and may give rise to a liquidated claim for defamation or/ and breach of contract. All issues can be resolved amicably. An issue, contact me first. If you have any issues with your item, let me know and I will be happy to rectify any problem. If you post negative or neutral feedback without first letting me know of your intention to post such feedback will be deemed defamatory and may give rise to proceedings for defamation and/or breach of contract and will give rise to a liquidated claim for damages. If you have in issue, it would be quicker to contact me first and I will do my utmost to help you. If you do not wish to have feedback posted for you – for privacy reasons or otherwise – just let me know and I will not post feedback for you or simply do not post feedback for me. All brand names & trademarks are the property of their respective holders and are referred to here for descriptive purpose only. The listed brand names and model designations are intended only to show the compatibility of these products with various products. Pictures are for descriptive purposes only. All dimensions and measurements are approximate. Colour is as shown unless otherwise stated. Colour may vary depending on lighting, your computer screen resolution or angle of viewing. Please exercise care when you open your package when you receive it. Do not slash the packing material with a knife as to damage the contents of the package. Open carefully so you don’t drop the contents in case of fragile or breakable items. If the information is not correct, please provide your correct contact information. Any dispute arising out of this. Agreement or the interpretation thereof. Shall be decided and. Settled in accordance with the laws and statues of the State of New South Wales, Australia. The parties agree that the venue shall be Sydney, New south Wales. This item is in the category “Industrial\Building Materials\Insulation & Accessories\Insulation”. The seller is “eddiesolomon777″ and is located in this country: AU. This item can be shipped worldwide.
  • Custom Bundle: No
  • Material: Foil backed bubble wrap
  • Type: Foil Bubble Insulation
  • Features: Heat Retardant
  • Insulation R-Value: R2
  • MPN: SFBI1
  • Product Type: Insulation
  • Modified Item: No
  • Packaging: Roll
  • Brand: INSULATION ACADEMY
  • Suitable For: Car, Caravan, Campervan, Truck, Boat, Dog House, Water Bottle, Esky, Chocolate, Keep Food Fresh, Attic/Loft, Basement, Ceiling, Floor, Garage, Interior Wall
  • UPC: 0602401607958

Silver Foil Cell Air Bubble Insulation 40 M L 750mm W Australian Csiro Tested